10.02. limits
the table is intended to list the minimum and maximum values you
can assign to programmable variables;
m.u. from
to
product
sec.
0
20
0 = no product;
product start delay
sec.
0
20
0 = no delay;
water time
sec.
0
20
0 = no water;
water start delay
sec.
0
20
0 = no delay;
water flow
low, medium, high
mixer
sec.
0
20
0 = no mixer;
mixer start delay
sec.
0
20
0 = no delay;
mixer speed
low, medium, high
temperature boiler
°C
0
95
product decounter
sec.
0
6.000
0 = no limit;
machine code A and B
n.
0
65.535
message number
n.
0
7
fan delay
min.
0
180
beep time
sec.
0
1,5
tuning pump
+/- 30%
tuning motor
+/- 30%
MAN1890105 rel. 02 dated 08.03.2017
page no. 30 of 38
www.rheavendors.com tel: 0039 02 966 551 fax: 0039 02 96 55 086 e mail: [email protected]
rheavendors group's sole property
XX micro by