09.01.m. out of service
09.01.n. product qty
09.01.o. maintenance
09.01.p. rfid card
to display the recording of the twenty errors last occurred in the
machine; press key “2” to scroll the records and key “4” to reset
the recording (see 11.);
each product motor can be assigned a time credit in seconds that
will be decreased at each dispensing cycle of that product; after
having used up the credit, the machine will answer <<selection not
available>> whenever a request is made for that product; this
control is disabled at the beginning and the machine has got no
constraint; to programme the credit time of a product motor, set
the variable by pressing key “4” and “5”;
after having reached the time quantity you wish, press key
“PROG”; the value will be copied between parentheses on the left
of the display;
programmable products from 1 to 6;
quit the programming mode as usual;
please note that the first warning threshold can be programmed; if
exceeded, the display will show an alarm message without
interfering with the operation of the machine;
after having used up the time credit, the operator may decide
whether to inhibit or not the dispensing cycle of the selections,
including that product;
an operator, which can not access the programming mode because,
for example, does not know the password, once the containers
loaded with the appropriate products may can set all the values
products decounters at their original values; to do this, he has only
to keep pressed button “PROG” for about 10-15 seconds until the
display shows:
in this ensemble of parameters, key “2”, you can set up some
counters to trigger an alarm after a programmable number of
events (press “4” and “5” to set up and PROG to store):
- dispensing cycles before having to replace the cartridge of the
external filter, if any; as soon as 500 dispensing cycles are left,
the display will show “change water filter” and as soon as the
decounter has reached 0, it will display “out of service water
filter”, thus inhibiting the operation of the machine;
- espresso dispensing cycles before having to service the coffee
brewer; as soon as 5 dispensing cycles are left, the
display will show “make brewer cleaning” and as soon as the
decounter has reached 0, it will display “out of service cleaning
brewer”, thus inhibiting the operation of the machine;
- espresso dispensing cycles before having to empty the grounds
container ; as soon as the decounter has reached 5, it will display
the
message
“remove
coffee
grounds”
until
the
decounter has reached 0, thus inhibiting the operation of the
machine and the display will show “out of service coffee
grounds”;
- the maximum credit you can load from the RFID card;
- 0 for each coin (from A to J) that can be accepted when the RFID
card is available;
- 0 for each coin (from A to J) that can be accepted when the RFID
card is not available;
MAN2100160 rel. 00 dated 05.11.2013 page no. 35 of 53 pages
www.rheavendors.com tel: 0039 02 966 551 fax: 0039 02 96 55 086 e mail: [email protected]
exclusive property of rheavendors group
n. N off NN
hh:mm dd-mm-yyyy
product qty N
[ 0.0] 170.0
product qty N
[170.0] 170.0
prod. N warning
thresold: 17.0
enable stop prod. N
1=stop 0
SET PRODUCT
=====OK=====
dec. cof. grounds
[ 00] 00
dec. cof. brewer
[ 00] 00
water filter cnt
[ 00] 00
coin A N
with card 0=acc.
coin A N
no card 0=acc.
max credit card
0.00
Cino XS grande PRO and PRO VHO