WARNING:
ENSURE HYDRAULIC HOSES ARE PROPERLY CONNECTED AND IN GOOD CONDITION.
5.
Ensure that the hydraulic fluid supply is adequate.
6.
Attach the red battery lead to the positive battery terminal, and the black lead to the negative terminal. Tighten each wing
nut with a pair of pliers, as even a slightly loose connection can cause the battery terminals to heat up. Keep battery
terminals clean with a corrosion protective coating.
WARNING:
FOLLOW THE SAME SAFETY RULES WHEN WORKING INSIDE THE POWER SUPPLY BOX
AND AROUND THE BATTERY THAT APPLY TO ANY CAR OR BOAT BATTERY. A BATTERY
CAN EXPLODE AND CAUSE PERSONAL INJURY AND/OR EQUIPMENT DAMAGE.
7.
Verify that the system is switched “on” using the on/off switch located inside the power supply box on the side of the
electrical control box.
8.
If the optional solar panel is supplied, the solar panel must be mounted in a suitable location. Mount the solar panel so
that it faces toward the south and angled toward the afternoon sun. Route the plug end of the solar panel through the
flexible cable boot in the back of the control box. Connect to the mating connector in the wiring harness.
9.
If the optional AC charger is supplied, mount the charger to left side of the box. Connect the red wire to the positive
battery terminal. Connect the black wire to the battery negative terminal. Run the AC power cord through the flexible
cable boot in the back of the control box and plug the AC charger in.
10.
If the optional light bar will be used on the lift, route the light bar wire through the flexible cable boot in the back of the
control box and plug into the light connector. Using UV stabilized nylon cable ties, (black zip ties) attach the wire and
the hydraulic hoses to the lift frame.
3.10
OPERATING POSITION
After moving your lift to the operating position, ensure that the bottom lift frame assembly is square and sets level. Measure
diagonally the inside edge of rear extension leg to inside edge of opposing front extension leg. Repeat for alternate corners.
Lift is considered square when the
difference between the two measurements shall not exceed 1/4 of an inch
.
CAUTION:
SEVERE OUT OF LEVEL INSTALLATION MAY CAUSE BINDING, RESULTING IN
EQUIPMENT DAMAGE.
Frame Diagonal Measurement Diagram
(Measure to Inside Corners)
12