Level limit switch
Series RF 3000
Technical Information / Instruction manual
page
metal-metal
sealing
welding with
container wall
Flush welding
socket
Dimension of flush welding socket (for optional on site manufacturing):
Surfaces in contact with
process Ra <=0.8um
Section A
Section B
Dimensions in mm
* suggested values
(in brackets values to be
adhered bindingly)
Metal-metal sealing:
• The support must be plane and without any gap. No teflon tape (or similar) is allowed to be in between.
• Fixing torque 100Nm
The quality of the welding with the container wall must be according to the respective regulations (e.g. gaps, transitions, surface
finish).
Mounting
EHEDG Approval
Total length L + 9mm (0.35")
RFnivo
®
1
2
3
4
5
6
7
8
9
10
11
12
RF 3000 d
gi241014
15