EFR32BG22
Shenzhen RF-star Technology Co., Ltd.
Page 43 of 93
AT+SCAN_PHY?
Function
Query the PHY layer of the device during scanning and connection.
Example
AT+SCAN_PHY?
Return Value
AT+SCAN_PHY=0
OK
Remark
The current PHY layer of the device during scanning and connection is 1 M PHY (by default).
AT+SCAN_PHY=
Function
Set the PHY layer of the device during scanning and connection.
Example
AT+SCAN_PHY=1
Return Value
OK
Remark
Set the scan PHY of the current master role to LE CODED PHY. After setting LE CODED PHY, it
can only scan the slave devices under the same LE CODED PHY, and can only connect to the
device under LE CODED PHY.
Take effect immediately after setting, can be saved after power off.
Note: RF-BM-BG22A1 and RF-BM-BG22A1I do not support this command.
•
Scan and Print Out Slave Device Name
AT+S
_
NAME=?
Function
Query the parameter range of this command.
Example
AT+S_NAME=?
Return Value
AT+S_NAME=[0,1]
OK
Remark
0: Stop scanning the slave device name. 1: Start scanning the slave device name.
Only effective in master mode and master-slave mode.
AT+S
_
NAME?
Function
Query the status of this function.
Example
AT+S_NAME?
Return Value
AT+S_NAME=1
OK
Remark
0 means the current scan status is stopped.
1 means the current scan status is scanning.
Summary of Contents for EFR32BG22
Page 71: ...EFR32BG22 www szrfstar com V1 6 Jun 2022 Shenzhen RF star Technology Co Ltd Page 70 of 93...
Page 75: ...EFR32BG22 www szrfstar com V1 6 Jun 2022 Shenzhen RF star Technology Co Ltd Page 74 of 93...
Page 76: ...EFR32BG22 www szrfstar com V1 6 Jun 2022 Shenzhen RF star Technology Co Ltd Page 75 of 93...
Page 77: ...EFR32BG22 www szrfstar com V1 6 Jun 2022 Shenzhen RF star Technology Co Ltd Page 76 of 93...
Page 91: ...EFR32BG22 www szrfstar com V1 6 Jun 2022 Shenzhen RF star Technology Co Ltd Page 90 of 93 CE...