background image

EZTEXT 

 

DS-EZTEXT-6 

User set-up commands

 

Title  

Command  

Description  

Example  

Password  

UPW  

   

UPW#UNITPW  

User  must  send  UPW  command  within  5  mins  after 

power applied. Setting the UPW is carried out by send-

ing this text message to the unit.  

   

The User Password (4 

 8 Characters) is case sensitive 

and can consist of any letters or numbers.  

If  for  any  reason  the  unit  password  is  lost,  remove  all 

power for 1 minute, and then start again. 

Note : Default password is 1234  

 

   
UPW#1234  
(sets password to 

1234)  
   
Response:  
UPW OK  
   

   

Unit identity  

UID  

   

UNITPW#UID#UNITID  

This sets the ‘identity’ of the EZTEXT unit, and will be 

included in any response text from EZTEXT.  

The UNITID  can be 4 to 10 characters.  

  

   
1234#UID#Door Alarm  

   

Response:  
Door Alarm UID OK  

   

Response  

RESPONSE  

RESPONSE? 

   

UNITPW#RESPONSE#x  

Setup a Reply Text EZTEXT after receiving a command  

x=ON or OFF  

   

UNITPW#RESPONSE?  

Requests the status of the current RESPONSE setting  

   

NOTE:  messages  which  specifically  demand  a  response 

such  as  requests  for  input  status  will  always  be  re-

sponded to as will the UPW, UID etc.  

Default setting is for response to be turned ON.  

  

   
1234#RESPONSE#ON  

Turns on Response 

messages  

   

1234#RESPONSE?  

Replies with the EZ-

TEXT setting to re-

sponses  

   

Text Message Commands

 

Error Messages and Factory Reset 

There are three error messages; 
NO AUTHORISATION    

 

Means that EZTEXT did not accept the password  

 
UNRECOGNIZED COMMAND  

Password correct but the command is incorrect 

 

UNRECOGNIZED VARIABLE   

Password and command OK but the variable data is in-

correct  

 
Factory reset 

Hold down the RESET button for  approx10 

seconds until all LEDs flash, then release. 

This will reset EZTEXT to factory default 

settings and restart. 

Please note that the following characters can be used as character separators 

Has h“#”, Comma “,” or Space “ “ 

 

For example  
1234#out1#ON  or  1234,out1,ON  or   1234 out1 ON 

Reset switch

Summary of Contents for EZTEXT

Page 1: ...rs if its input is activated or at a temperature set point A user can control EZTEXT switches by sending text messages Custom mes sages may be set easily via configuration text messages GSM Remote Con...

Page 2: ...you go SIM which require regular top up to remain active It is recommended to bar Incoming voice calls to the SIM card to avoid error messages being sent back to the user This can be achieved by call...

Page 3: ...r All Flash ON OFF together Error No GSM Service 1 Check SimCard 2 Check Antenna Connection 30 20 10 RX TX 4 LED Indication after start up normal operation Good OK Poor Signal Strength Activity LED s...

Page 4: ...ptional Battery Optional external antenna Using an external antenna can provide a much better signal reception than the internal antenna unplug the antenna connection Use cable adaptor CBA UFLSMA 1 to...

Page 5: ...ommand x ON or OFF UNITPW RESPONSE Requests the status of the current RESPONSE setting NOTE messages which specifically demand a response such as requests for input status will always be re sponded to...

Page 6: ...input 2 Set number of input activations before SMS sent IPCNT IPCNTVAL Sets the number of times an input must be acti vated before an SMS is sent UNITPW IPCNTn x n input number 1 or 2 x Counter 0 to 6...

Page 7: ...replies with the preset time delay output and the actual time that the output has been activated for Note the Timer counts down from the preset time de lay 1234 OPDLY1 500 Sets output1 to operate for...

Page 8: ...s all the tele phone numbers associ ated with Temperature monitoring Set maxi mum trigger temperature SETTEMPMA X UNITPW SETTEMPMAX n Sets the maximum temperature trigger level in degrees Celsius 1234...

Page 9: ...solation purposes Electrical Characteristics Min Typical Max Dimension Notes Supply Voltage 9 26 V Supply Current for EZTEXT Idle Operating 24 100 35 250 45 2000 mA mA 1 2 Closed Contact Input Time 10...

Page 10: ...ma tipa definirani u ovom dokumentu u skladu s Direktivom 2014 53 EU Cjeloviti tekst EU izjave o sukladnosti dostupan je na sljede oj internetskoj adresi www rfsolutions co uk HU RF Solutions Limited...

Reviews: