background image

EZTEXT 

 

DS-EZTEXT-6 

INPUT Commands

 

Title  

Command  

Description  

Example  

Set an input 

name  

IPNAME  

IPNAME?  

   

When the input changes this is the name that the 

EZTEXT will transmit in its text message  

   
UNITPW#IPNAMEn#<name>  
This  designates  a  <name>  to  an  EZTEXT  input 

(max15 characters)  

n=1 - 4  for inputs1 to 4  

   

UNITPW#IPNAME?  

Requests the name given to all inputs  

   

1234#IPNAME1#Gate  

Sets input 1 to be 

known as ‘Gate’

  

   

1234#IPNAME?  

Requests the current 

name of input1  

Input number 

to text  

   

IPNUM  

IPNUM?n  

IPNUMDEL  

Sets the destination phone number(s) (max 5 per 

input)  when an EZTEXT input is activated. 

  

UNITPW#IPNUMn,<num to text> 

n=1 - 4  for inputs1 to 4 

  

UNITPW#IPNUM?n 

Requests all Stored cell Nos for that input 

  

UNITPW#IPNUMDELn 

n=1 - 4  for inputs1 to 4 

Deletes all stored cell Nos for that input number 

  

   

   
1234#IPNUM1#00441

234567891  
Sets tel No to input 1  

   

1234#IPNUM?1  
Requests all stored 

telephone numbers for 

input 1  

   

   
1234#IPNUMDEL2  
Deletes ALL stored       

numbers for input 2  

   

Set number of 

input               

activations   

before SMS 

sent  

   

 IPCNT  

   

   

IPCNTVAL?  

Sets  the  number  of  times  an  input  must  be  acti-

vated before an SMS is sent  

   

<UNITPW#IPCNTn#x  

n= input number (1 or 2)  

x= Counter (0 to 65500)  

   

   

UNITPW#IPCNTVAL?  

Requests the actual current value of the counter 

   
   
1234#IPCNT1#10  
A text will be sent after 

input  1  has  been  acti-

vated 10 times  
   

1234#IPCNTVAL?  

Responds with ;  
INTPUT1= 10/4  
intput1 has been  

activated 4 times,  

6 more activations  

required  before  text  is 

sent  

  

Delay SMS on 

input activa-

tion  

 IPDLY  

IPDLY?  

Sets a timer (Max 65500 secs). When the EZTEXT 

input is activated the timer starts to countdown in 

seconds.  

When the counter reaches zero, providing the input 

is still activated a text message will be sent.  

   

UNITPW#IPDLYn#xx  

n=1 - 4  for inputs1 to 4  

‘xx’ can be a number from 0 to 65500

  

   

UNITPW#IPDLY?  

Requests timer values for all inputs  

  

Note: When combined with IPCNT each activation of 

Input must be for the extended time 

   

   

   

1234#IPDLY1#60  

Input 1 has a 60sec 

delay before text is sent  

   

   

1234#IPDLY?  

Responds with ;  
INTPUT1= 60/34  

(output1 has been ac-

tive for 34 out of a total 

60sec preset time. 

34secs more is required 

before text sent)  

Summary of Contents for EZTEXT

Page 1: ...rs if its input is activated or at a temperature set point A user can control EZTEXT switches by sending text messages Custom mes sages may be set easily via configuration text messages GSM Remote Con...

Page 2: ...you go SIM which require regular top up to remain active It is recommended to bar Incoming voice calls to the SIM card to avoid error messages being sent back to the user This can be achieved by call...

Page 3: ...r All Flash ON OFF together Error No GSM Service 1 Check SimCard 2 Check Antenna Connection 30 20 10 RX TX 4 LED Indication after start up normal operation Good OK Poor Signal Strength Activity LED s...

Page 4: ...ptional Battery Optional external antenna Using an external antenna can provide a much better signal reception than the internal antenna unplug the antenna connection Use cable adaptor CBA UFLSMA 1 to...

Page 5: ...ommand x ON or OFF UNITPW RESPONSE Requests the status of the current RESPONSE setting NOTE messages which specifically demand a response such as requests for input status will always be re sponded to...

Page 6: ...input 2 Set number of input activations before SMS sent IPCNT IPCNTVAL Sets the number of times an input must be acti vated before an SMS is sent UNITPW IPCNTn x n input number 1 or 2 x Counter 0 to 6...

Page 7: ...replies with the preset time delay output and the actual time that the output has been activated for Note the Timer counts down from the preset time de lay 1234 OPDLY1 500 Sets output1 to operate for...

Page 8: ...s all the tele phone numbers associ ated with Temperature monitoring Set maxi mum trigger temperature SETTEMPMA X UNITPW SETTEMPMAX n Sets the maximum temperature trigger level in degrees Celsius 1234...

Page 9: ...solation purposes Electrical Characteristics Min Typical Max Dimension Notes Supply Voltage 9 26 V Supply Current for EZTEXT Idle Operating 24 100 35 250 45 2000 mA mA 1 2 Closed Contact Input Time 10...

Page 10: ...ma tipa definirani u ovom dokumentu u skladu s Direktivom 2014 53 EU Cjeloviti tekst EU izjave o sukladnosti dostupan je na sljede oj internetskoj adresi www rfsolutions co uk HU RF Solutions Limited...

Reviews: