© 1996-2005 RF IDeas, Inc. All rights reserved
Timing
Get/Set Internal Timing
Data is valid for
The time the card ID remains valid in the device. Once this time elapses, the card data is discarded.
The minimum value is 900.
Inter-key 'Press' time
Sets USB inter-key Press' time delay in msecs. This is how long the key is held down.
Inter-key 'Release' time
Sets USB inter-key 'Release' time delay in msecs. This is the delay between keystrokes.
Lock-out time for repetitive reads
The lock-out time is the time, in milliseconds, that a subsequent output is prevented. The reader checks
to see if the same card remains on the reader, If it is the same card, the reader will wait this period of