12
/16
Bosch Rexroth AG
Hydraulics
VT-HACD-3-2X RE 30543/12.10
X3C, Interface for BODAC
X7P, Bus interface
X7E1(2), Ethernet interface
RS232
PROFIBUS DP (max. 12 MBaud according to IEC 61158)
PROFINET RT, EtherNet/IP
Switching inputs (DI) and/or outputs (DO)
Quantity DI = 9 / D0 = 8
Gate inputs (DI)
Logic level log 0 (low)
≤
5 V; log 1 (high)
≥
10 V to
U
B
,
I
e
= 7 mA at
U
B
= 24 V
Port Flexible conductor up to 1.5 mm
2
Gate outputs (DO)
Logic level log 0 (low)
≤
2 V; log 1 (high)
≤
U
B
;
I
max
= 20 mA,
Maximum load capacity C = 0.047µF
Port Flexible conductor up to 1.5 mm
2
Reference potential for all signals
GND
Digital position transducer (encoder)
– Incremental transducer (transducer with TTL output)
• Input voltage
log 0 0 to 1 V
log 1 2.8 to 5.5 V
• Input current
log 0 –0.8 mA (with 0 V)
log 1 0.8 mA (with 5 V)
• max. frequency referring to Ua1
f
max
250 kHz
– SSI transducer (Due to the higher control quality, an SSI
transducer with clock synchronization should be used.)
• Coding
Gray code, binary code
• Data width
Adjustable up to max. 28 Bit
• Line receiver / line driver
RS485
– Voltage supply for SSI transducer via the VT-
HACD-3-2X
U, I U
B
,
max. 200 mA
Reference potential for all signals
GND
Reference voltage per axis electronics
U
ref
+10 V ±25 mV (20 mA)
Dimensions
See page 14
Installation
Top hat rail TH 35-7.5 or TH 35-15 according to EN 60715
Admissible operating temperature range
ϑ
0 to 50 °C
Storage temperature range
ϑ
–20 to +70 °C
Protection class according to EN 60529:1991
IP 20
Weight
without EtherNet module
with EtherNet module
m
m
930 g
1162 g
CE conformity
See page 2
Further technical details upon request.
Note:
Information on the
environment simulation testing
for the areas EMC (electromagnetic compatibility), climate and mechanical
load see data sheet 30543-U.
Technical data,