background image

 

CS 550/150RC Towplow 

Spreader Joystick Controller Operator Manual 

 

Summary of Contents for CS 550/150RC

Page 1: ...CS 550 150RC Towplow Spreader Joystick Controller Operator Manual...

Page 2: ...ylinder Symbol 11 4 6 Programming Mode Lock Symbol 12 5 Operator ID Input 13 6 Joystick Control 13 6 1 Joystick Screen 13 6 2 Button Status 13 6 3 Joystick Status 14 7 Spinner Reverse Mode 14 8 Air Ga...

Page 3: ...3 17 Bosch Rexroth Canada August 2018 Revision 2 0 1 Panel Controls Turn knobs clockwise to increase...

Page 4: ...ation Screen Layout SPNR SALT LIQUID1 Spinner Label Spread Width Spinner Setpoint Spinner Mode Pause Button Solid Name Gate Mode Solid Rate Gate Position Conv Set Conveyor Mode Blast Button Liquid Nam...

Page 5: ...e and press again to resume spreading 3 2 Blast Press the Blast button to increase the spreading output and press again to resume regular rate 3 3 Reverse Press and hold the Reverse button to change t...

Page 6: ...l button again to confirm and save the selection Press the oval button with the LIQUID1 text to adjust the material type Note vehicle must be stationary Use the Left and Right arrows to adjust Press t...

Page 7: ...e ground speed 0 pop up the UP Dn arrows press hold the UP arrow for 5 seconds to enable the simulated ground speed Use the up and down arrows to adjust speed with an increment of 5 3 7 Error Messages...

Page 8: ...8 TOW 3Boom Anti icing DLA If the TOW is configured as 3 Boom Anti icing DLA the SPINNER AND CONVEYOR will be disabled Note Only external boom switches are supported for TOW 3Boom Anti icing operatio...

Page 9: ...isplay most recent error messages If a hydraulic pressure temperature sensor is connected both readings will be displayed on the bottom right of the screen A program key is required to clear the error...

Page 10: ...be stationary Turn the dials until the desired speed is achieved Press the symbol again and to exit unload mode Moving the vehicle will suspend the unload process It will automatically resume when th...

Page 11: ...lume Adjustment Press the Bright Vol symbol to enter into adjustment mode volume or bright Press again to toggle the other mode If AutoDimr is checked in setup the brightness automatically change Use...

Page 12: ...rs by press the Lock symbol to enter into Sync mode sync on the lock symbol when both rate positions are the same and the ground speed is 0 Pressing the symbol again would turn the Sync mode off Note...

Page 13: ...and if enabled a keyboard will pop up to allow input Press the Enter key to save 6 Joystick Control For systems equipped with Joystick Option ONLY 6 1 Joystick Screen Available only when equipped wit...

Page 14: ...direction the joystick handle deflected The mode status is always displayed at the top right of the screen and the voice output audibly lets the operator know the mode selected 7 Spinner Reverse Mode...

Page 15: ...off blast reset timer ERROR DEICE BLST TOO LONG 2 Turn off blast reset timer ERROR OVERSPEED 3 Slow down reset max speed ERROR SPIN PROP 4 Check cables replace coil ERROR CONV PROP 5 Check cables repl...

Page 16: ...R 34 Min null or gate too high OVER APPLICATION PREWET 35 Min null too high rate too low OVER APPLICATION ANTI ICING 36 Min null too high rate too low CALIB GND SPD PULSES TOO LOW 37 Too few or no pul...

Page 17: ...High GATE ZERO IN MANUAL 56 Manual Gate set to 0 GATE AT CALIBRATION TOO LOW 57 Calibrated gate needs tob a non zero value SPINNER SENSOR PULSES TOO LOW 58 Spinner sensor pulses 0 or too low CONV SEN...

Reviews: