7. A temperature switch is provided to control oil sump
temperature. See Figure 2 for proposed wiring.
There are two separate circuits in the temperature
switch. The low circuit is to operate the electric fan.
It is recommended the fan motor be operated by
the temperature switch through a motor starter relay
(consult applicable local and national electrical codes).
The high circuit is provided to operate either a high
temperature alarm or main motor shutdown.
L
1
L
2
PROPOSED TEMPERATURE SWITCH WIRING
DIAGRAM FOR ELECTRIC FANS
CONTROL VOLTAGE
SWITCH
FALK PART NO.
932716
- NEMA 4 & 13
LOW CIRCUIT
START FAN
MOTOR
MS
RED
BLUE
PURPLE
SET AT 140°F
(60°C)
HIGH CIRCUIT
YELLOW
ORANGE
ALARM OR MAIN MOTOR
CIRCUIT
BROWN
SET AT 210°F
(100°C)
MS = MOTOR STARTER
CUSTOMER WIRING
AND COMPONENTS
AC RATING - INDUCTIVE LOAD - 50% PF
DC RATING - INDUCTIVE LOAD - L/R = 0.26
AC
VOLTS
AMP
AMP
DC
VOLTS
125
250
480
15
15
15
MAXIMUM CONTINUOUS CURRENT
∗∗
Reference only.
6-12 **
24 **
125
250
15
5
0.05
0.03
Figure 2
POSITION A
POSITION B
POSITION C
1
1
2
Mounting Positions
For Position
A & B
Remove Plug 1
For Position
C
Remove Plug 2
Note: Never use
copper or brass
fastening materials
Figure 3
8. Connect power to the motor using an approved wiring
method. See Figure 1 for connection diagrams.
9. Before starting the fan, double check to ensure there
are no obstructions that could interfere with proper
fan operation and airflow. Verify proper fan rotation,
resulting in air flow directed at the adjacent face of the
gear drive.
10. Remove proper condensation plug. See Figure 3
below. Do not discard. Plug is to be used during
cleaning.
NOTES
:
AIR SUPPLY AND TEMPERATURE
— Sufficient air supply
over the motor must be assured in all circumstances.
Limits of operating ambient temperature are 14°F to 113°F
(–10°C to 45°C).
RESTRICTION ON USE
— Fan blade material
is Polypropylene which is unsuitable and/or not
recommended for certain chemicals. The following is a
partial list of unsuitable chemicals for guideline purposes.
Chloro-Sulphonic Acid
Nitric Acid Chloroform
Mixture of HNO3-HCL
Esters
1:2 Trichloroethylene
Mixture of HNO3-H2SO4
Benzene
Trichloroethylene
Sulfuric Acid, fuming
Gasoline
Diethyl Ether
Carbon Tetrachloride
Toluene
Chlorine, Liquid
Chlorobenzene
Xylene
CLEANING
— When cleaning fan, both condensation
holes (Figure 3, Items 1 and 2) are to be temporarily
plugged. If this is not done, guarantee is void. When
cleaning electrical equipment, always use an approved
cleaning agent.