sources and the temperature of the place in which
the appliance is installed must not rise above 50°C.
The appliance must also be connected to an equi-
potential earth. This connection can be made using
the equipotential terminal marked with the symbol
, placed under the appliance near the right rear
foot. The equipotential wire must have a section of
10mm2.
TRASFORMATION AND ADAPTATION
Connection to the distribution network, installation, and maintenance of the ap-
pliance must only be carried out by qualified technicians only, in observance of all
applicable regulations!
COOKTOP BURNERS:
1. Remove burner body and lid.
2. Replace nozzle with a suitable one for the new type of gas indicated in the nozzle table.
3. Restore the initial condition.
MINIMUM:
1. Pull the knobs off and remove the control panel if necessary.
2. Adjust the minimum by-pass nozzle fig.16.
3. Restore the initial condition.
OVEN BURNER:
1. Remove the base of the oven fig.15, unscrew and lift the burner, unscrew and replace the nozzle with a
suitable one for the new type of gas indicated in the nozzle table.
MINIMUM:
1. Pull the knobs off and remove the control panel if necessary.
2. Adjust the minimum by-pass nozzle fig.16.
3. Restore the initial condition.
If the bottom of the oven chamber is removed, it must be put back in exactly the
same position.
7
EN