When checking for leaks do not use naked flames!
The manufacturer shall not be held responsible and the guarantee is void in the
case of damage caused by negligence in following the operating and installation
instructions or by improper use. The guarantee is void in the case of connections
which have been made in a way which doesn’t meet the current standards and
fire-fighting regulations.
EVACUATION OF BURNT GASES: A1 APPLIANCE
Appliances must be installed under an extraction hood with forced draught, subjected to gas supply.
CHECKING THE PRESSURE
The distribution network pressure must meet the following specifications.
LPG
ALLOWED from 20/25 to 35/45 mbar
NOT ALLOWED below 20/25 above 35/40 mbar
METHANE - H
ALLOWED from 17 to 25 mbar
NOT ALLOWED below 17 above 25 mbar
If the gas distribution network pressure on the in-
stallation site doesn’t meet the above values, in-
form the gas board and do not turn the unit on until
the cause and a solution have been found.
The distribution network pressure can be taken
with a U manometer (min. definition 0.1 mbar),
connected to the pressure outlet behind control
panel.
1. Remove the control panel.
2. Remove the screw and sealing washer from the
pressure outlet and connect the manometer.
3. Turn the unit on following the enclosed instruc-
tions and check that the pressure is within the per-
mitted pressure range.
4. Disconnect the manometer and replace the
screw and the sealing washer in the pressure out-
let.
5. Replace the control panel.
ELECTRICAL CONNECTION
Before proceeding with the electrical connection, check the specifications on the
data plate. The appliance is supplied with a power cable (3x1,5 H07RN-F).
The installer must make the connection after hav-
ing installed a standard plug connected to an easy-
to-reach socket, or in case of a permanent connec-
tion, after having installed a main switch, which, as
well as being easy to reach, must disconnect all of
the contacts supplying electrical energy to the ap-
pliance, with a minimum distance of at least 3mm
between the poles. The earth wire must never be
disconnected.
The power cable must not be installed near heat
6
EN