Install the blower and capacitor in locations that meet the following conditions.

Indoors (the product is designed and manufactured to be mounted in a machine)

0

0

Ambient temperature -10C  ~ +50C  

Ambient humidity 0 ~ 85 % (Non-condensing)

No explosive, flammable, and / or corrosive gas.

No exposure to direct sunlight.
No splashing of water or exposure to dust or debris.
No oil or grease, organic solvents, acid or alkaline chemicals.

No continuous vibration or excessive shock.

4. Installation

Wiring Diagram

TM

Contact Us @ +91 7769827676, 9637419123, +91 20 24699118, 65237108, 64700160.

TM

                       
       www.fhpgearedmotors.com

Red

White

Black

Black

Short Black wires and connect the capacitor

Wiring diagram for Single Phase Blower

Red-2

Black-2

Red-1

Black-1

~

Ensure that the impeller is rotation in 

anti clockwise direction,

 air flow is maximum.

as shown.
To change the direction, connect the supply
wire from White to Red.

Red wires are for running winding and 
Black wires for Starting winding.
To change the direction, interchange
Black wires or Red wires.

Wiring diagram for Three Phase Motors

Standard Single Phase Blower

SR Type Single Phase Blower

~

Star Connection

Delta Connection

U

Brown

V

Red

W

Yellow

Black

Blue

White

Blue

Red

U

White

Brown

V

Yellow

Black

W

For the  Voltage 415 VAC, 3-Phase Supply, Wires 
are connected as shown in the fig.
Short Blue, Black and White and then insulate it 
carefully.

To change the direction, interchange any two wires 
between U, V & W.

For the  Voltage 230 VAC, 3-Phase Supply, Wires 
are connected as shown in the fig.
Short Blue & Red, Black & Yellow, and White& Red 
as per the fig. Shown. 

To change the direction, interchange any two wires 
between U, V & W.