CB series blower is equipped with one of two methods to prevent burning the blower as a result of abnormal heating

Impedence Protection

 

( CB 100836)

The blowers are designed with higher impedence in the motor windings so that even if the motor locks, the increase
 in current is kept down hence the temperature does not rise beyond certain constant level.
 
Thermal protection (CB121255, Cb161270, )
When the blower reaches a predetermined temperature, the internal thermal protector is activated and the blower
is stopped.

With the automatic resume feature, the blower automatically begins operation again as soon as the blower 
temperature falls to a certain level. Always turn the power off before performing inspections.

0

0

0

0

Operating temperature of thermal protectors : Open : 120C    5C  ,  Close : 77C    15C

5. Overheat Protection

www.fhpgearedmotors.com

A  mounting  bracket  matching  the  diameter  of  the 
motor  casing 

is  available. 

With  this  mounting 

bracket,  a  blower  can  be  secured  to  the  equipment 
by  using  the  motor  casing  section  of  the  blower.
While  installing  a  blower,  be  sure  to  use  a  spacer  so 
that the impeller casing does not touch the surface to which 
the mounting bracket is secured.

4.1 Mounting the blower

Use of mounting bracket (Option

)

Air flow Direcion

M

ounting on a Plate

4. 2 Mounting the capacitor 

(For only single-phase types)

Before  mounting 

the  capacitor, 

check  the

capacitance of the capacitor provided, matches the
capacitance indicated on the blower’s nameplate.
Use clamp to mount the capacitor

Air flow 

Rotation

Plate

Note :

 Install the capacitor at least 10cm, away from

the motor as the capacitor life span may be shorten 
due to heat from the blower.