*** NEVER USE AN OPEN FLAME FOR LEAK TESTING.***
When using copper or flex connectors use only fittings approved for gas connections. The
gas control inlet is 3/8" NPT, therefore the 1/2" rigid gas line must be reduced to 3/8" NPT.
A typical gas line installation layout for rigid pipe is shown on the previous page.
VENTING (COAXIAL 6" AIR INTAKE & 4" EXHAUST)
Kits are available for venting either through the sidewall or vertically through the roof.
SIDEWALL VENTING
MINIMUM
VENT LENGTH:
NATURAL GAS MODELS : 5' AND ONE 90 DEGREE ELBOW PROPANE
MODELS
: 8' AND TWO 90 DEGREE ELBOWS
FOLLOW THE VENTING INSTRUCTIONS ON THE FOLLOWING PAGES
PRECISELY BEFORE BEGINNING THE INSTALLATION, TAKING CARE TO
ENSURE THAT AN APPROPRIATE OUTSIDE LOCATION FOR THE VENT
TERMINATION CAN BE ACCOMMODATED (SEE NEXT PAGE).
IMPORTANT
: THE INTAKE AIR REGULATING SHUTTER, LOCATED INSIDE
THE COMBUSTION CHAMBER OF THE APPLIANCE, MUST BE SET TO THE
VENT LENGTH USED IN THE INSTALLATION OF THE APPLIANCE. FAILURE
TO SET THE SHUTTER WILL RESULT IN POOR PERFORMANCE OR
COMPLETE SHUT-DOWN OF THE APPLIANCE.