6
ORIFICE SIZES:
(REAR OR TOP VENT)
FRONT BURNER:
NATURAL
#57DMS
PROPANE
#67DMS
NATURAL
#57DMS
PROPANE
#67DMS
REAR BURNER:
#47DMS
#56DMS
#49DMS
#57DMS
Manifold Press:("W.C.)
3.5"
10.0"
3.5"
10.0"
Min. Manifold Press:
1.5"
5.2"
1.5"
5.2"
Max. Supply Press:
7.0"
13.0"
7.0"
13.0"
Min. Supply Press:
3.5"
10.5"
3.5"
10.5"
Max. BTUH Input:
22,000
20,000
19,800
18,000
Mm. BTUH Input:
15,000
15,000
13,500
13,500
STEADY STATE EFFICIENCY:
FAN OFF (MIN. VENT L): 71.7 %
FAN ON (MAX. VENT L): 74.1 %
74.3%
95.7%
AFUE/DOE (USA):
Natural Gas
Propane
Minimum vent (5’), 1 elbow, fan OFF
63.76%
—
Minimum vent (8’), 2 elbows, fan
OFF
—
64.07%
Maximum vent (35’), 2 elbows, fan ON
DIMENSIONS:
72.99%
78.61%
Front Width:
34"
Height:
36" (Top Vent)
34" (Rear Vent)
Depth:
12.5"
Shipping Weight: 98 lbs.
CLEARANCES TO COMBUSTIBLES:
Sides
:2"
Rear
:2"
Top
:2"
Floor
: 0"
Above : 6"
CORNER INSTALLATIONS - CLEARANCES TO COMBUSTIBLES: AS ABOVE WITH 2"
CLEARANCE TO CORNER OF THE APPLIANCE
Always observe the approved clearance to combustible materials.
ELECTRICAL REQUIREMENTS
A 120 volt electrical power supply is required to operate the REVERSO "SUPREME"
DVF200 built-in forced draft fan. The Millivolt gas control which uses the pilot flame to