background image

Cup

RT 400D

RT 520D

RT 700D

Product Size

Ø3.6 x 4.3 (in)

Ø3.6 x 5.3 (in)

Ø3.6 x 6.9 (in)

Product Weight

0.04 lb

0.05 lb

0.06 lb

Capacity

Max

13.8 oz

17.9 oz

23.7 oz

Optimal

12 oz

16 oz

20 oz

Packaging Size

18.9 x 15.4 x 21.5 (in)

Packaging Weight

18.5 lb

22 lb

20.9 lb

Packaging Unit

440 EA

400 EA

300 EA

Certification

FDA certified

by SGS

CE

LFGB

MID

FDA

NSF

Single Unit

Twin Unit

RD B1

RD BF1

RD BL2

Product Size

9.4 x 11.8 x 3.6 (in)

8.7 x 10.8 x 3.9 (in)

13.8 x 14.8 x 5.5 (in)

Product Weight

3.3 lb

16.5 lb

Packaging Size

14.4 x 13 x 5.6 (in)

17.3 x 16.8 x 8.4 (in)

Packaging Weight

6.6 lb

18.5 lb

Packaging Unit

1 EA

1 EA

Certification

FDA certified 

by SGS

CE

LFGB

FCC

KC

FDA

LCD 

Display

-

7 Inch

(155x88 mm)

Voltage / Hz

100-240 V / 50-60 Hz, 1.5 A

ReverseTap Dispenser Specification

ReverseTap Cup Specification

M16

23

Summary of Contents for RD B1

Page 1: ...Operation Manual Ver 1 1 ReverseTap WWW REVERSETAP COM ...

Page 2: ...ts proper installation the device might not perform properly or be damaged NPC Co Ltd is not liable for any damages or injuries that may occur due to improper installation Please read this manual carefully before use to ensure safe and proper usage Descriptions are based on the device s default settings Images and screenshots may differ in appearance from the actual product Contents of this manual...

Page 3: ...l outlet when the device is not in use Do not place the device or power cord near heat sources such as flammable spray Turn off the power if there is a risk of lightning when used outdoor Keep vinyl packaging wrap of the device and other small parts out of reach of children Do not put any parts into the dishwasher or use scouring powder benzene thinner and chlorine bleach for cleaning This may cau...

Page 4: ...D display 9 How to set the value of each mode 10 SETUP Mode Size setting Mode 11 FOB Mode 12 Foam Mode Cleaning Mode 13 Shortcuts to frequently used functions Advanced Functions 14 Advanced Mode Unit Mode 15 Security Mode 17 TIME VOLUME Mode 18 Tracking Mode LED Mode 19 AUTO MANUAL mode FLOW SENSOR Mode 20 Maintenance 21 Troubleshooting 23 Product Specification 24 Warning on use of ReverseTap Cup ...

Page 5: ...k inside of the packaging box for the list of components in a separate print Cover gripper nozzle are already assembled into the dispenser when shipped in the packaging box USB memory for LCD monitor is not included Unauthorized accessories might cause damage to the device Appearances and specifications are subject to change without prior notice If accessory is lost or damaged you can purchase it ...

Page 6: ...ut Front view Back view Control panel view Top view Cup sensor Gripper Nozzle LED Single Tall Single Flat Twin Premium There is no power switch on Single type dispenser Adapter USB Flow sensor Power Switch Audio 6 ...

Page 7: ...long beep sound Only for Single model For Twin Premium dispenser use the power switch to turn on Start button cannot turn on the Twin Premium model Reset Press and hold both the Right and Left button at the Standby status for two seconds Then if you enter correct password and press and hold set button for two seconds all the settings will be restored to the initial factory setting values with a lo...

Page 8: ...ed it is displayed as Off Dispensing status This signal indicates the amount of dispensed beer and the status that beer is being dispensed Percentage and time While dispensing the percentage and elapsed time of each beer cup is displayed Dispensing This text indicates the Dispensing status It notifies that beer is being dispensed Finished This indicates the Finished status FOB Mode This text indic...

Page 9: ...p and Down button Press Left and Right button to shift to the next mode Once all changes are complete long press the Set button to save the changes and return to the Standby status FOB status Once FOB mode is activated after the warning signal the display will show options between Start and Stop KEG Alarm Mode This text notifies that KEG Alarm mode is activated Users can set the Alarm mode to chec...

Page 10: ...scharge of beer when it reaches any desired amount Long press the Set button and then the discharged amount will be automatically set as the preset size of Medium If you want to change the amount of each preset size you can change it in Size setting Mode Pressing any other button will take you back to the initial screen of Sync Mode without saving SETUP Push Start Size setting Mode In this mode us...

Page 11: ...p dispensing Step by step procedure to replace with the new KEG 1 Check the KEG whether it is empty or not Shake the KEG 2 If it is empty you need to change the KEG with the new one 3 Press Stop button to turn off FOB mode 4 Close the middle valve of CO2 tank and replace the KEG with the new one 5 If you dispense a few cups of beer with the new KEG those beer foam remaining in the cooler and the t...

Page 12: ...ntact the distributor 2 Connect the tube with the nozzle and place the end of the tube into the drain basket 3 Lock the middle valve of CO2 tank and change the beer KEG to the cleaning KEG Cleaning KEG and cleaning chemicals can be purchased from the market 4 Open the middle valve of CO2 tank and press Start button twice 5 The valve will open and cleaning function will start Text on the display wi...

Page 13: ... Cleaning Mode Foam Mode Size setting Mode FOB Mode FOB on FOAM on 1650 oz READY 16 oz Standby Status Shortcuts to frequently used functions Please use at standby status 13 ...

Page 14: ...ume Time Mode 8 Mode to change calibration coefficient of flow sensor 6 Auto Manual Mode 7 KEG Alarm Mode Flow Sensor Coefficient 1 15 Volume Time Auto Manual KEG Alarm Alarm OFF Flow rate 62 5 mL s Volume 18000 mL Unit oz ml 1 Unit Mode Security Mode Setting Lock ON Dispensing Lock ON Password 2 Security Mode Unit Mode In unit select mode users select a unit that they will use ReverseTap provides...

Page 15: ... prefer To save long press the SET button This will switch back to the Standby status How to change the settings while Setting Lock is ON In Standby status long press the Set button It will ask for a password with a screen Settings are locked Input the correct password to enter the settings mode This does not change the password This is only for entering the settings mode Setting Lock is continuou...

Page 16: ...n to the Standby status Ready screen Shortcuts for Security Mode Shortcut for Setting Lock OFF ON Long press the Left button on Standby status Ready screen to turn ON the Setting Lock Shortcut for Setting Lock ON OFF Long press the Left button on Standby status Ready screen and input a correct password to turn OFF the Setting Lock Shortcut for Dispensing Lock OFF ON Long press the Right button on ...

Page 17: ...ns SMALL 5 8 s 11 5 oz Size setting Mode in TIME Mode How to change the PRESET size in TIME Mode SMALL 11 5 oz Size setting Mode in VOLUME Mode TIME VOLUME Small Medium Large Press Up and Down button to select a size s seconds Press Up and Down button to input dispensing time for each size In TIME Mode press Up and Down button to adjust dispensing time by 0 1 Estimated volume is shown below dispen...

Page 18: ... is inserted in ReverseTap State Press Up and Down button to select before during or the after dispensing Before Set LED lighting after a cup is inserted and before dispensing Dispensing Set LED lighting during dispensing Dispensed Set LED lighting after dispensing is complete The lighting will continue until the cup is removed Mode Press Up and Down button to select the desired color LED Mode Sta...

Page 19: ...e AUTO MANUAL Press Up and Down button to select AUTO or MANUAL AUTO MANUAL FLOW SENSOR Mode A function to enclose the gap between the Preset volume and the actual dispensed volume Coefficient Press Up and Down button to adjust the value Default 1 15 If the actual volume is more than the Preset volume Lower the coefficient If the actual volume is less than the Preset volume Raise the coefficient I...

Page 20: ...pen CO2 gas valve Switch to a cleaning nozzle and connect it to a hose to discharge to a drain or a bucket Continue draining until you see clean water Close CO2 gas valve and discharge the remaining CO2 gas Immerse the coupler into a clean water after separating it Circulate clean water through entire beer line to clean them on daily basis Also replace the lines with new beer line regularly For a ...

Page 21: ...comes out from the chiller s Overflow gate Is the chiller operated for fair amount of time You must fill the chiller with water and operate 24 hours prior to beer dispensing for regular beer discharge If using kegerators are the kegs cooled enough It varies by the beer type but you must cool the keg down to around 4 C for at least 24 hours before use Is not the inside of the chiller frozen too muc...

Page 22: ... keep the keg in cool place so the keg is maintained in a recommended temperature Did you see bubbles passing in beverage lines when dispensing Remove bubbles from beverage lines Discharge beer raising gas pressure by 50 kPa but do not exceed 400kPa Are not the beverage line bent too much or leaking Exchange the beverage lines and insulate them For tube shortage please contact CSC Keypad does not ...

Page 23: ...rtification FDA certified by SGS CE LFGB MID FDA NSF Single Unit Twin Unit RD B1 RD BF1 RD BL2 Product Size 9 4 x 11 8 x 3 6 in 8 7 x 10 8 x 3 9 in 13 8 x 14 8 x 5 5 in Product Weight 3 3 lb 16 5 lb Packaging Size 14 4 x 13 x 5 6 in 17 3 x 16 8 x 8 4 in Packaging Weight 6 6 lb 18 5 lb Packaging Unit 1 EA 1 EA Certification FDA certified by SGS CE LFGB FCC KC FDA LCD Display 7 Inch 155x88 mm Voltag...

Page 24: ...80 Supported Memory Card USB Flash Memory Power Consumption 5W Operating Temperature 10 60 Power Output DC 5V 1A Input 100 240V 24 Cups only for ReverseTap of RT400D RT520D RT700D are disposable plastic cups Therefore it is not recommended using more than once We do not hold any responsibility for all issues arising from multiple time use of disposable cups If damaged due to use of product besides...

Reviews: