X. OPERATING PARAMETERS 

& SAFETY MEASURES:

The following conditions for feed water supply  

MUST be met or Warranty will be void.:

1.  Unit MUST be connected to a municipal or well water  
 

source that is treated and tested on a regular basis to  

 

insure water is microbiologically safe.

2.  Operating temperatures: 
 

Maximum:   105  °F   ( 40.6 °C ) 

 

Minimum:  50   °F  

( 15 °C )

 

 

CAUTION!! DO NOT ALLOW SYSTEM TO FREEZE. The membrane always  

contains water and will be destroyed if frozen.

3.  Maximum Operating Pressure MUST NOT EXCEED 120 PSI. 
 

(

Waste  out from membrane housing line , and before  flow restrictor)

WARNING!! Warranty voided and manufacturer assumes no responsibility  

for damage to system or property if pressure exceeds 120 PSI.

4.  Inlet Pressure: 
 

Maximum:  80 PSI 

 

Minimum:   40 PSI

At pressures lower than 40 PSI production and quality of water 

supply will be reduced and operating at pressures greater than 

120 psi may be severe damage to the system, for which it is  

recommended to measure the following parameters.

5.  Turbidity:   < 1 NTU
6.  pH Range : 4 – 11
7.  We recommend the following parameters NOT TO EXCEED:

• 

Total Hardness: NOT TO EXCEED 7 grains/gal ( 120 ppm )

• 

Sulfide, Iron and Manganese: < 0.001 ppm

• 

Residual Chlorine In Water Supply: < 1.5 ppm

8.  Recommended Total Dissolved Solids (TDS)  
 

NOT TO EXCEED 1,000 ppm.

XI. TROUBLESHOOTING AND SOLUTIONS GUIDE

Symptom

Posible Cause

Solution

LOW QUANTITY OF WATER 

FROM HOLDING TANK

Feed water valve is plugged or closed.

Open the feed water valve or unclog.

Pre-filter o post-filter are saturated or clogged.

Replace Filters.

Low incoming water pressure. 

Your booster pump may not be operating properly.  

If damaged correct or replace. Check the low pressure switch  

is operating correctly.

Reverse Osmosis Membrane is fouled.

Make sure feed water pressure is within operating limits. Make sure 

drain line is not clogged. Check the water quality parameters  

and correct the cause of fouling and replace RO membrane.

Air pressure in holding tank is incorrect.

Empty water from holding tank. Air pressure in valve stem should be 

between 8 - 10 PSI.

Air Bladder in Holding Tank is ruptured. 

If the tank has a way to change the membrane do it, or replace for a 

new tank. 

Holding tank valve is closed.

Open tank valve.

No water to drain. Drain Flow Restrictor is clogged..

Replace Drain Flow Restrictor.

Check Valve on RO Membrane Housing is stuck.

Replace Check Valve.

The Solenoid Valve in the feed it is not operating properly.

Verify if you are getting electrical power and for any obstruction not 

allowing water passage.

RO-300G & RO-600G

Operating Parameters  | Troubleshooting

RO-300G-600G_manual.indd   10

6/28/16   3:57 PM

Summary of Contents for RO-300G

Page 1: ...Installation Manual RO 300G RO 600G W A T E R P U R I F I C A T I O N S Y S T E M RO 300G 600G_manual indd 1 6 28 16 3 57 PM ...

Page 2: ... 8 c Atmospheric Tank Configuration 8 VIII Quick Connectors 9 IX Precautions and Tips 9 X Operating Parameters 10 XI Troubleshooting and Solutions Guide 10 XII Liability and Warranty 12 WARNING READ ENTIRE MANUAL FAILURE TO FOLLOW ALL GUIDES AND RULES COULD CAUSE PERSONAL INJURY OR PROPERTY DAMAGE CHECKWITHYOUR STATE AND OR LOCAL PUBLICWORKS DEPARTMENT FOR PLUMBING CODES WARNING DO NOT USEWITHWATE...

Page 3: ...e system shuts down and when no feed water pump switch has no team The RO 300G RO 600G models are a basic version of a business osmosis model with attractive price and guarantees a salt retention of up to 97 Please be sure to read this manual before proceeding with the installation to become familiar with the terms and parties II COMPONENTS IDENTIFICATION AND SPARE PARTS FOR MAINTENANCE Model Desc...

Page 4: ... ORGANICS OR INOR GANICSTHAT COULD ATTACKTHE MEMBRANE MATERIAL ALWAYSTURN OFFTHE UNIT SHUT OFFTHE FEEDWATER AND DISCONNECTTHE ELECTRICAL POWER BEFOREWORKING ONTHE UNIT NEVER ALLOWTHE PUMPTO RUN DRY NEVER ALLOWTHE UNITTO FREEZE OR OPERATEWITH A FEEDWATERTEMPERATURE ABOVE 100 F WARNING WARRANTY ISVOID AND COMPANY ASSUMES NO RESPONSIBILITY FOR SYSTEM OR PROPERTY DAMAGE IF THE SUPPLY PRESSURE IS OVER ...

Page 5: ...er day in consideration of 24 hrs of operation The flow of water flowing into the drain is called wastewater and is measured in Gal Day The feedwater flow is the sum of currents product water and waste water d Percent Recovery It is another way to measure the amount of water produced compared to the amount of water used Formula Percent Recovery Product H2O Rate x 100 Feed H2O Rate e Water Pressure...

Page 6: ...nk in its final position then the hydraulic preparations corresponding thereto Do not forget to place a key storage tank outlet that will help in future repairs and maintenance of their post treatment to close the line of purified water Before electrically connecting the system to make sure there are no leaks in the supply line opening the stopcock if it detects any leakage repair it before contin...

Page 7: ...least let the water run for five minutes and then check that there is no presence of chlorine in the water with a chlorine kid Once this rinsing process is completed close again the water feed valve Reemplace the cartridges and membrane and make sure the filter and membrane housings are tighten up Remember to move the exterior oring towards the side of the cap of the membrane housing Tighten with ...

Page 8: ...H SOLENOID VALVE PUMP MANUAL FLUSH VALVE FLOW RESTRICTOR CHECK VALVE HIGH PRESSURE SWITCH SHOKBLOK CARBON SEDIMENT CARBON CARBÓN SEDIMENTO CARBÓN SWITCH DE BAJA PRESIÓN VÁLVULA SOLENOIDE BOMBA ALIMENTACIÓN DE AGUA RESTRICTOR DE FLUJO RO 300G FLOW CHART RO 600G FLOW CHART FEED WATER PRESSURE GAUGE LOW PRESSURE SWITCH PUMP MANUAL FLUSH VALVE FLOW RESTRICTOR CHECK VALVE HIGH PRESSURE SWITCH SHOKBLOK ...

Page 9: ... may cause the filter housings to become brittle and fracture The supply pressure must always be taken into account and measured before installation of the system since the maximum tolerance pressure of 75 PSI is referred to by the manufacturer For safety we recommend installing a pressure regulator before feeding the system when you have more than 60 PSI in the inlet water to avoid stress in the ...

Page 10: ...ual Chlorine InWater Supply 1 5 ppm 8 RecommendedTotal Dissolved Solids TDS NOTTO EXCEED 1 000 ppm XI TROUBLESHOOTING AND SOLUTIONS GUIDE Symptom Posible Cause Solution LOW QUANTITY OF WATER FROM HOLDING TANK Feed water valve is plugged or closed Open the feed water valve or unclog Pre filter o post filter are saturated or clogged Replace Filters Low incoming water pressure Your booster pump may n...

Page 11: ...olding Tank is full Check for blockage inside the solenoid valve and check if electrical current is reaching the high pressure swicth or level switch Carbon postfilter has not been rinsed enough Drain the holding tank to allow the fine particles of the new carbon block cartridge to be expelled The incoming feed water TDS has increased An increase in feed water TDS will also give an increase in Pro...

Page 12: ...ect alteration water pressure spikes accident or negligence and provided further that the Reverse Osmosis DrinkingWater System is not damaged as the result of any unusual force of nature such as but not limited to flood hurricane tornado or earthquake Warrantor is excused if failure to perform itsWarranty obligations is the result of strikes government regulation materials shortages or other circu...

Reviews: