1.INTRODUCTION 

    

1.1 PRECAUTIONS 

    

1.2 TRANSPORT 

    

1.3 PACKAGE CONTENT 

    

1.4 USE 

2. DEVICE CHARACTERISTICS 

    

2.1 CONSTRUCTION AND PRINCIPLE OF OPERATION

    

2.2 DEVICE DIMENSIONS

    

2.3 DEVICE TECHNICAL DATA

3. ASSEMBLY

    

3.1 GENERAL PRINCIPLES

    

3.2 ROTATING MOUNTING BRACKET

4. INSTALLATION INSTRUCTIONS 

    

4.1 CONNECTION OF THE DEVICE TO THE HYDAULIC SYSTEM 

    

4.2 CONNECTION OF THE DEIVCE TO THE ELECTRICAL SYSTEM 

5. PRECAUTIONS & WARNINGS
6. CONTROLS 
7. CONNECTION SCHEMES
8. TERMS OF WARRANTY

  ENG

 

     

 

T ECHNICAL DOCUMENTATION

1. 

INTRODUCTION

Thank  you  very  much  for  purchasing  air  water  heater 

.  We  would  like 

to congratulate you on excellent choice. Please read and keep this manual. 

1.1  

PRECAUTIONS

The buyer and the user of the air water heater Reventon Group brand should 
read  carefully  the  following  instructions  and  proceed  to  the  content 
recommendations.    Proceeding  due  to  the  following  instruction  guarantees 
the  correct  usage  and  safety.  In  case  of  any  doubts  please  contact  directly 
Reventon  Group  sp.  z  o.  o.  [Ltd.].  The  producer  reserves  the  rights  to  make 
changes  to  the  technical  documentation  without  previous  notice.  Reventon 
Group  sp.  z  o.  o.  [Ltd.]  is  not  responsible  for  the  damages  which  occur  due 
to  improper  installation,  not  keeping  the  device  in  repair  or  using  the  device 
out of line. The installation should be carried out by the professional installers, 
who possess the qualifications to install these types of devices. The installers 
are responsible for making the installation as instructed in the technical data. 
In  case  of  unserviceable  please  plug  out  the  device  and  contact 
with  the  authorizedfor  repair  person  or  the  supplier.  During  the  installation, 
use,  service  and  periodical  inspections  all  regulations  and  safety  rules 
must be followed.

1.2  TRANSPORT

During  the  acceptance  of  goods,  it  is  needed  to  check  the  device  to  exclude 
any damages. During the transport, it is needed to use the proper equipment, 
it is necessary to carry the device by two people. In case of any damages please fill 
in the damage report in presence of the supplier.

1.3  

PACKAGE CONTENT

- h

eater

- o

peration and maintenance manual and warranty card

HC-EC

1.4 

USE 

 

Heating  devices  Reventon  Group  HC  series  are  used  to  heat  spaces  such  as: 
production  halls,  warehouses,  commercial  room,  service  spaces,  garages, 
workshops,  greenhouses,  tents,  shops,  malls,  shopping  malls  etc.    However, 
heating  devices  should  not  be  used  in  corrosive  environments  for  aluminum, 
copper  and  steel  as  well  as  in  highly  dusty  environments  (above  0.3  g/m³). 
The  devices  should  not  be  installed  in  rooms  where  they  would  be  exposed 
to high humidity or direct contact with water. 

2. 

DEVICE CHARACTERISTICS 

2.1 

CONSTRUCTION AND PRINCIPLE OF OPERATION

Casing: 

made of expanded polypropylene (EPP). This material is characterized 

by  low  density  (light  weighted)  and  high  chemical  and  physical  resistance. 
It has an excellent sound and thermal insulation properties. Moreover, material 
is environmentally friendly and "green", i.e. 100% recyclable.

Air  stators:

  made  of  polypropylene  PP.  It  is  possible  to  adjust  manually 

the  air  stators  to  achieve  the  needed  direction  of  the  air  flow.  There  are  also 
versions  with  confusor  (increased  airflow  range)  or  with  diffuser  360° 
(better mixing of supplied and room air).

Heating coil: 

made of copper and aluminum. Supplied by distribution medium 

(heating or cooling), which circulates through the coil and releases or extracts 
heat from the air. The coil has the following technical parameters: the maximum 
temperature of the heating factor is 120°C; maximum pressure 1.6 MPa; headers 
diameter ¾”. Depending on dimensions of the device the heaters are equipped 
with 1, 2 or 3-row heating coils. 

Axial blowing fan: 

made of steel.

 The objective of the fan is to ensure air flow 

through the exchanger. It has a single-phase brushless EC motor characterized 
by  high  energy  efficiency  and  wide  range  of  speed  control  (voltage  signal 
from 1.7 V to 10 V). Its parameters are following: IP44 protection rating, rated 
current 1.5 or 2.0 A (depending on model). The models HC 20-EC, HC 30-EC, 
HC 35-EC and HC 45-EC have a fan with a diameter of 400 mm, and the HC 50-EC 
and HC 70-EC with a diameter of 450 mm.

Rotating  mounting  bracket  (optional  equipment): 

enables  the  device 

to  be  installed  in  several  configurations  (depending  on  the  requirements) 
and the unit to be rotated in a horizontal plane. 

2.2 

DEVICE DIMENSIONS

- HC 20-3S, HC 30-3S, HC 35-3S and HC 45-3S:

ź

 

598 mm

ź

 

636 mm

ź

 

 

3

2

0 mm

HC 50-3S, HC 70-3S and HC 80-3S:

ź

 

698 mm

ź

 

739 mm

ź

 

3

3

0 mm

height (A)
width (B)
depth

(C)

height (A)
width (B)
depth 

(C)

Model

HC 3 A

HC 5 A

HC 7 A

3

3

3

3

1

1

2

5

5

5

5

2

2

4

8

8

8

8

3

3

6

HC20-3S

HC30-3S

HC35-3S

HC45-3S

HC50-3S

HC70-3S

HMI

HC3S

3

3

3

3

1

1

2

5

5

5

5

2

2

4

HC 14 A

RM- 16 A

16

16

16

16

7

6

12

19

19

19

19

8

7

14

HC80-3S

HC 1.2 A

1

1

1

1

-

1

-

COOPERATION OF CONTROLLERS WITH EQUIPEMENT

Summary of Contents for HC 20-EC Series

Page 1: ...Technical documentation AIR WATER HEATERS IN EPP CASING HC EC SERIES MODELS HC 20 EC HC 30 EC HC 35 EC HC 45 EC HC 50 EC HC 70 EC ...

Page 2: ...ing devices Reventon Group HC series are used to heat spaces such as production halls warehouses commercial room service spaces garages workshops greenhouses tents shops malls shopping malls etc However heating devices should not be used in corrosive environments for aluminum copper and steel as well as in highly dusty environments above 0 3 g m The devices should not be installed in rooms where t...

Page 3: ...1 03 0 92 HC 30 EC 4100 m h 0 5 10 15 20 25 6 23 2 20 9 18 6 16 4 17 4 21 0 24 7 28 2 31 8 1 12 1 02 0 92 0 82 0 72 80 60 90 70 40 30 120 90 HC 20 EC 4300 m h HC 20 EC 4300 m h HC 20 EC 4300 m h HC 20 EC 4300 m h HC 30 EC 4100 m h HC 30 EC 4100 m h 6 5 4 4 3 7 6 5 5 4 5 5 4 3 2 4 3 2 2 1 1 1 0 0 0 5 3 2 1 0 8 7 7 6 5 11 9 8 7 5 8 7 5 4 3 Parameters Supply return water temperature C Dry bulb air in...

Page 4: ...y kW Dry bulb air outlet temperature C Water flow m h Pressure drop in the heat exchanger kPa Parameters Supply return water temperature C Dry bulb air inlet temperature C Heating capacity kW Dry bulb air outlet temperature C Water flow m h Pressure drop in the heat exchanger kPa Parameters Supply return water temperature C Dry bulb air inlet temperature C Heating capacity kW Dry bulb air outlet t...

Page 5: ...ers Supply return water temperature C Dry bulb air inlet temperature C Heating capacity kW Dry bulb air outlet temperature C Water flow m h Pressure drop in the heat exchanger kPa Parameters Supply return water temperature C Dry bulb air inlet temperature C Heating capacity kW Dry bulb air outlet temperature C Water flow m h Pressure drop in the heat exchanger kPa Parameters Supply return water te...

Page 6: ...al installation should be made by the qualified personnel who possess required authorizations to install electrical equipment basedonwiringschematicdiagrams see7 theelectricalinstallationofthebuildingshallhavearesidualcurrentdevice itisrecommendedtochecktheelectricinstallationandcontrolsbeforethefirst start 5 PRECAUTIONS WARNINGS The precautions mentioned below must be strictly followed during ope...

Page 7: ...from the controller In addition the device can be integrated with the BMS building control system usingtheMODBUScommunicationprotocol Voltage Frequency 230 V AC 50 60 Hz Maximum current 5 A Operating temperature range 0 45 C Regulation range 5 C 35 C Regulation accuracy 0 5 C External temperature sensor NTC 10K Communication RS485 Dimensions 86 x 86 x 13 3 mm Weight 270 g Degree of protection hous...

Page 8: ...r 2 Main switch overcurrent circuit breaker 3 Air water heater HC EC 4 Potentiometr EC 5 Programmable controller HMI EC 6 Valve with actuator HC 3 4 7 External temperature sensor main switch and safety fuses are not included in the set ...

Page 9: ......

Page 10: ......

Page 11: ...vedevicewithinaspecifiedtimelimit VII Warranty does not cover the parts of the device subject to normal maintenanceandthefollowingcases a mechanicaldamageoftheproduct b defectsanddamagesthrough improperstorageortransport improper or non compliant use and maintenance i e inconsistent withthemanual using the device in the improper conditions too high humidity too high ortoolowtemperature impactofthe...

Page 12: ...Warranty card Reventon Group Sp z o o Ltd 556 Wyzwolenia Street 43 340 Kozy Poland ...

Page 13: ...Reventon Group Sp z o o Ltd 556 Wyzwolenia Street 43 340 Kozy Poland www reventongroup eu ...

Reviews: