8. TERMS OF WARRANTY

I.  Producer  Reventon  Group  Sp.  z  o.o.  [Ltd.]  grants  the  buyer  a  24-month 
warranty period for the following devices:

- air water heater HC 20-EC
- air water heater HC 30-EC
- air water heater HC 35-EC
- air water heater HC 45-EC
- air water heater HC 50-EC
- air water heater HC 70-EC

II.  The  terms  of  warranty  are  valid  from  purchasing  the  device  (i.e.  invoice  / 
another confirming document issue date) but not longer than 30 months from 
leaving the producer's warehouse.

III. To obtain the service it is needed to provide or send to the producer scans 
of the warranty card with stamp of installation company, document confirming 
the purchase (eg. like copy of the invoice) and correctly filled the warranty form.

IV. The producer is committed to consider the claim within 14 working days since 
the date of reporting (i. e. day when documents given in point III are provided).

V. In the exceptional cases, the producer reserves the right to extend the time 
limit  for  examination  of  warranty,  especially  if  the  defect  is  not  permanent 
and  its  determination  requires  a  longer  period  of  time.  The  extension  must 
be notified by the producer before the end of the 14th working day.

VI.  Under  the  guarantee  the  producer  provides  a  repairment,  replacement 
or refund for the defective device within a specified time limit.

VII.  Warranty  does  not  cover  the  parts  of  the  device  subject  to  normal 
maintenance and the following cases:

a) mechanical damage of the product

b) defects and damages through:
- improper storage or transport
-  improper  or  non-compliant  use  and  maintenance  (i.  e.  inconsistent 
with the manual)
-  using  the  device  in  the  improper  conditions  (too  high  humidity,  too  high 
or too low temperature, impact of the surrounding, sun etc.)
-  unauthorized  (by  the  user  or  other  unauthorized  persons)  repairs, 
modifications or construction changes
- connecting equipment inconsistent with the technical documentation
- connecting additional equipment, which is not recommended by the producer
- improper power supply

c) elements which wear and tear such as discolor of the housing

If there is any of the above, claimant will be charged for transport and / or repairs
.
VIII. Any changes in the Warranty Terms, improper use of the product (careless 
handling,  exposure  to  liquids,  moisture,  corrosion),  as  well  as  traces 
of selfrepairing (non by the Reventon Group) or alterations cause, the warranty 
is not valid.

IX. Not following to any of warranty regulations makes the warranty not valid.

X.  All  correspondence,  returns,  complains  should  be  send  to  the  following 
address: Reventon Group Sp. z o.o. [Ltd.], 556 Wyzwolenia Street, 43-340 Kozy, 
Poland or email address: [email protected].

The  producer  reserves  the  rights  to  make  changes  to  the  technical 
documentation without previous notice.

Model

HC 3 A

HC 5 A

HC 7 A

3

3

3

3

1

1

2

5

5

5

5

2

2

4

8

8

8

8

3

3

6

HC20-3S

HC30-3S

HC35-3S

HC45-3S

HC50-3S

HC70-3S

HMI

HC3S

3

3

3

3

1

1

2

5

5

5

5

2

2

4

HC 14 A

RM- 16 A

16

16

16

16

7

6

12

19

19

19

19

8

7

14

HC80-3S

HC 1.2 A

1

1

1

1

-

1

-

COOPERATION OF CONTROLLERS WITH EQUIPEMENT

Summary of Contents for HC 20-EC Series

Page 1: ...Technical documentation AIR WATER HEATERS IN EPP CASING HC EC SERIES MODELS HC 20 EC HC 30 EC HC 35 EC HC 45 EC HC 50 EC HC 70 EC ...

Page 2: ...ing devices Reventon Group HC series are used to heat spaces such as production halls warehouses commercial room service spaces garages workshops greenhouses tents shops malls shopping malls etc However heating devices should not be used in corrosive environments for aluminum copper and steel as well as in highly dusty environments above 0 3 g m The devices should not be installed in rooms where t...

Page 3: ...1 03 0 92 HC 30 EC 4100 m h 0 5 10 15 20 25 6 23 2 20 9 18 6 16 4 17 4 21 0 24 7 28 2 31 8 1 12 1 02 0 92 0 82 0 72 80 60 90 70 40 30 120 90 HC 20 EC 4300 m h HC 20 EC 4300 m h HC 20 EC 4300 m h HC 20 EC 4300 m h HC 30 EC 4100 m h HC 30 EC 4100 m h 6 5 4 4 3 7 6 5 5 4 5 5 4 3 2 4 3 2 2 1 1 1 0 0 0 5 3 2 1 0 8 7 7 6 5 11 9 8 7 5 8 7 5 4 3 Parameters Supply return water temperature C Dry bulb air in...

Page 4: ...y kW Dry bulb air outlet temperature C Water flow m h Pressure drop in the heat exchanger kPa Parameters Supply return water temperature C Dry bulb air inlet temperature C Heating capacity kW Dry bulb air outlet temperature C Water flow m h Pressure drop in the heat exchanger kPa Parameters Supply return water temperature C Dry bulb air inlet temperature C Heating capacity kW Dry bulb air outlet t...

Page 5: ...ers Supply return water temperature C Dry bulb air inlet temperature C Heating capacity kW Dry bulb air outlet temperature C Water flow m h Pressure drop in the heat exchanger kPa Parameters Supply return water temperature C Dry bulb air inlet temperature C Heating capacity kW Dry bulb air outlet temperature C Water flow m h Pressure drop in the heat exchanger kPa Parameters Supply return water te...

Page 6: ...al installation should be made by the qualified personnel who possess required authorizations to install electrical equipment basedonwiringschematicdiagrams see7 theelectricalinstallationofthebuildingshallhavearesidualcurrentdevice itisrecommendedtochecktheelectricinstallationandcontrolsbeforethefirst start 5 PRECAUTIONS WARNINGS The precautions mentioned below must be strictly followed during ope...

Page 7: ...from the controller In addition the device can be integrated with the BMS building control system usingtheMODBUScommunicationprotocol Voltage Frequency 230 V AC 50 60 Hz Maximum current 5 A Operating temperature range 0 45 C Regulation range 5 C 35 C Regulation accuracy 0 5 C External temperature sensor NTC 10K Communication RS485 Dimensions 86 x 86 x 13 3 mm Weight 270 g Degree of protection hous...

Page 8: ...r 2 Main switch overcurrent circuit breaker 3 Air water heater HC EC 4 Potentiometr EC 5 Programmable controller HMI EC 6 Valve with actuator HC 3 4 7 External temperature sensor main switch and safety fuses are not included in the set ...

Page 9: ......

Page 10: ......

Page 11: ...vedevicewithinaspecifiedtimelimit VII Warranty does not cover the parts of the device subject to normal maintenanceandthefollowingcases a mechanicaldamageoftheproduct b defectsanddamagesthrough improperstorageortransport improper or non compliant use and maintenance i e inconsistent withthemanual using the device in the improper conditions too high humidity too high ortoolowtemperature impactofthe...

Page 12: ...Warranty card Reventon Group Sp z o o Ltd 556 Wyzwolenia Street 43 340 Kozy Poland ...

Page 13: ...Reventon Group Sp z o o Ltd 556 Wyzwolenia Street 43 340 Kozy Poland www reventongroup eu ...

Reviews: