2. DEVICE CHARCTERISTICS
2.1 DIMENSIONS
1. INTRODUCTION
1.1 PRECAUTIONS
1.2 TRANSPORT
1.3 PACKAGE CONTENT
1.4 USE
2.DEVICE CHARCTERISTICS
2.1 DIMENSIONS
2.2 TECHNICAL DATA
3. INSTALLATION
3.1 GENERAL PRINCIPLES
3.2 ASSEMBLY „STEP BY STEP”
4. INSTALLATION INSTRUCTIONS
4.1 CONNECTION OF THE DEIVCE TO THE ELECTRICAL SYSTEM
5. PRECAUTIONS AND WARNINGS
6. CONTROLS
7.CONNECTION SCHEMES
8.TERMS OF WARRANTY
1. INTRODUCTION
Thank you for purchasing air curtain AERIS. We would like to congratulate
on good choice. Please read and save these instructions.
1.1 PRECAUTIONS
The buyer and the user of the device should read carefully the following
instructions and proceed to the content recommendations. Proceeding
due to the following instruction guarantees the correct usage and safety. In case
of any doubts please contact Reventon Group sp. z o. o. [Ltd.]. The
s
upplier
reserves the rights to make changes to the technical documentation without
previous notice. Reventon Group sp. z o. o. [Ltd.] is not responsible
for the damages which occur due
to improper installation, not keeping the device
in repair or using the device out of line. The installation should be carried
out by the professional installers, who possess the qualifications to install these
types of devices. The installers are responsible for making the installation
as instructed in the technical data. Regulations and safety rules
must be followed. During the installation, use, service and periodical inspections
all regulations and safety rules must be followed. In case of unserviceable please
plug out the device and contact with the authorized person or the
s
upplier.
All safety requirements must be taken into account during installation,
use or inspection.
1.2 TRANSPORT
During the acceptance of goods it is needed to check the device in order
to exclude any damages. During the transport it is needed to use the proper
equipment, it is necessary to carry the device by two people. In case
of any damages please fill in the damage report in presence of the
s
upplier
or the carrier.
1.3
PACKAGE CONTENT
-
air curtain
-
operation and maintenance manual and warranty card
-
assembly panel
-
door sensor
1.4
USE
Air curtains are widely installed at the entrances of supermarkets, theaters,
meeting rooms, hotels, offices, storages etc. They can reduce penetration
of insects, outside dust, unconditioned air into a conditioned space by forcing
an air stream over the entire entrance. In winter they prevent uncontrolled heat
loss and in summer they prevent heat from the room. However,
air curtains should not be used in corrosive environments for aluminum, copper
and steel as well as in highly dusty environments (above 0.3 g/m³).The devices
should also not be installed in rooms where they would be exposed
to high humidity or direct contact with water.
ENG
T ECHNICAL DATA
MODEL
REVENTON GROUP
AERIS 90EN-3P
REVENTON GROUP
AERIS 120EN-3P
REVENTON GROUP
AERIS 150EN-3P
A
B
C
D
E
F
900
1200
1500
132
90
19.0
22.5
G
N.W (KG)
15.5
440
---
---
---
---
---
---
247
218
H
230/50
230/50
230/50
AERIS 90EN-3P
AC90EN3P
AERIS 120EN-3P
AC120EN3P
AERIS 150EN-3P
AC150EN3P
8
10
12
11.5
14.5
17.3
III BIEG
II BIEG
I BIEG
III BIEG
II BIEG
I BIEG
III BIEG
II BIEG
I BIEG
III BIEG
II BIEG
I BIEG
III BIEG
II BIEG
I BIEG
1600
2400
3150
1450
2150
2850
1300
1950
2550
11
11
11
10
10
10
9
9
9
400/50
400/50
400/50
260
380
490
230
355
445
200
330
400
1.13
1.65
2.13
1.00
1.54
1.93
0.87
1.43
1.74
15.5
19.0
22.5
61
62
63
60
61
62
59
60
61
E / IP 20
E / IP 20
E / IP 20
Curtain's range [m]
II BIEG
3
3
3
WIRE SIZE FOR WIRING
WARNING: Forbid to overload operation for a long time!
Power supply
Power of heater [kW]
Minimum wire size of
2
Minimum wire size of
3-PHASE (400 V~,MAIN WIRE CONDUCTOR L1, L2, L3, N)
3
4
5
6
8
10
12
14
1.5
1.5
2.0
4.0
2.5
6.0
4.0
1.0
main wire conductor [mm ]
ground wire conductor [m ]
2
2.2.TECHNICAL DATA
Heater power [kW]
Rated heater current [A]
Maximum
airflow [m³/h]
Maximum
air speed
[m/s]
TECHNICAL DATA
Product code
Noise [dB]
Net weight [kg]
Class of isolation /Protection degree IP [-]
Rated motor
current [A]
Motor power [W]
Heater supply voltage [V] /
Heater supply frequency [Hz]
Motor supply voltage [V] /
Motor supply frequency [Hz]