4.
INSTALLATION INSTRUCTIONS
4.1.
CONNECTION OF THE DEIVCE TO THE ELECTRICAL SYSTEM
-
all works concerning electrical installation should be made by the qualified
personnel (who possess required authorizations to install electrical equipment),
based on wiring schematic diagrams (see 7)
-
the electrical installation of the building shall have a residual current device
-
check the electrical installation and automation before the first start
5.
PRECAUTIONS AND WARNINGS
During operation of the device, the following must be respected:
-
all works concerning electrical installation (disassembly, repair etc.) should
be made by the
qualified personnel, who possess the qualifications
due to the domestic and local norms, regarding electrical installations
-
do not limit or cover the inlet and outlet of the device
-
do not install, service the device with wet hands or barefoot
-
the device should be kept out of reach of children and animals
-
when no need heating, turn off the heat source to use it as an unheated
air curtain
-
after the turn off, the elements of device may be warm
-
after operating time of the device, please utilize it concerning the local norms
and regulations
-
don’t allow water or any liquid to enter the motor
-
maintenance and repair work must be carried out by a qualified personnel
familiar with local regulations and standards
-
always unplug or disconnect the appliance from the power supply before
installation, servicing or cleaning the unit
-
never use petrol, benzene, thinners or any other chemicals for cleaning the unit
-
periodic maintenance work should be carried out at least once a year by:
ź
cleaning the heater and other elements from dust
ź
cleaning of plastic parts with water with the addition of soap
ź
cleaning the casing with a soft cloth
- failure to comply with cleaning obligations may have a negative effect
on technical parameters of the device
and lead to loss of warranty
-
if the device is not used for a longer time disconnect the voltage supply
-
if any abnormality happens, turn off the product immediately and check
the problem
6.
CONTROLS
Usage of automatic control dedicated to the electric air heaters of Reventon
Group gives great possibilities of adjusting the efficiency of the curtain
in different, depending on needs, degree of automation of its operation. We also
offer additional controls:
is used to regulate devices equipped with 3-stage fans. It has a 3-stage speed
control and built-in thermostat switches the device of automatically when the
preset temperature is reached.
Voltage/ Frequency:
230 V AC / 50 – 60 Hz
Maximum current output
:
3 A
Temperature range:
10°C - 30°C
Operating mode:
continious or thermostatic
Control accuracy:
<1°C
Dimensions:
130 x 85 x 40 mm
Weight:
210 g
Degree of casing's protection:
IP 30