if the device is not used for a longer time disconnect the voltage suppl
-
if any abnormality happens, turn off the product immediately and check the
problem
6. INSTRUCTION OF USE
6.1
CONTROL
The air curtain can be controlled by a remote control or a control panel, located
on the housing (buttons are described in the same way), as described below:
a) Press "ON / OFF" to turn the device on. The main receiver gets a signal and
starts working with green light in a cold mode on the second fan speed (II stage).
Press "ON / OFF" button again to turn the device off.
b) Pressing the "COOL" button switches from the second to the first speed (I
stage). When the unit is in cold mode, pressing "COOL" button again will change
speed to high (II stage).
c)
To switch for the heating mode press "HEAT" button. The red light up on the
unit and it works in low-power heating mode. Pressing the "HEAT" button again
will cause the device to change its power to the medium (second heating stage),
which will be indicated with two red lights. Similarly, pressing the "HEAT" button
again will cause the device to change its power to high heating mode (it is
indicated by three red lights).
d) After another pressing of the "HEAT" button, the device changes to the cold
mode and the lights turns green.
6.2
OVERHEATING PROTECTION
The air curtain has overheating protection. If the temperature of the heater
exceeds the limit value, the device will switch to cooling mode and it will indicate
with the green light.
7. CONNECTION SCHEMES
LEGENDA:
1. Power
2. Main switch, overcurrent circuit breaker *
3. Water heated air curtain AERIS
4. Door switch
* main switch and overcurrent circuit breaker are not included in the unit