For heated rooms, set the steering wheel in the opposite direction to the room 
with the curtain at an angle of 0 -15 degrees (see figure).

For canteens, kitchens, set the steering wheel towards the room with the curtain 
at an angle of 0 -15 degrees (see figure).

2. DEVICE CHARCTERISTICS

2.1 DIMENSIONS

1. INTRODUCTION
        1.1. PRECAUTIONS
        1.2. TRANSPORT
        1.3. PACKAGE CONTENT
        1.4. USE
2. DEVICE CHARCTERISTICS
        2.1 DIMENSIONS
        2.2 TECHNICAL DATA  
3. INSTALLATION
        3.1. GENERAL PRINCIPLES
        

3.2. ASSEMBLY „STEP BY STEP”

4. INSTALLATION INSTRUCTIONS

       

4.1 CONNECTION OF THE DEIVCE TO THE ELECTRICAL SYSTEM 

5. PRECAUTIONS AND WARNINGS
6. INSTRUCTION OF USE

        

6.1 CONTROL

        

6.2 OVERHEATING PROTECTION

7. CONNECTION SCHEMES
8. TERMS OF WARRANTY

1. INTRODUCTION

Thank  you  for  purchasing  Reventon  Group  air  curtain.  We  would  like  to 
congratulate on good choice. Please read and save these instructions.

1.1 PRECAUTIONS

The  buyer  and  the  user  of  the  device  should  read  carefully  the  following 
instructions  and  proceed  to  the  content  recommendations.  Proceeding  due 
to  the  following  instruction  guarantees  the  correct  usage  and  safety.  In  case 
of any doubts please contact the Reventon Group Sp. z o.o. The Supplier reserves 
the  rights  to  make  changes  to  the  technical  documentation  without  previous 
notice.  The  Supplier  is  not  responsible  for  the  damages  which  occur  due 
to improper installation, not keeping the device in repair or using the device out 
of line. The installation should be carried out by the professional installers, who 
possess  the  qualifications  to  install  these  types  of  devices.  The  installers  are 
responsible  for  making  the  installation  as  instructed  in  the  technical  data. 
Regulations  and  safety  rules  must  be  followed.  During  the  installation,  use, 
service  and  periodical  inspections  all  regulations  and  safety  rules  must 
be followed. In case of unserviceable please plug out the device and contact with 
the authorized person or the Supplier. All safety requirements must be taken into 
account during installation, use or inspection.  

 1.2 TRANSPORT

During  the  acceptance  of  goods  it  is  needed  to  check  the  device  in  order 
to  exclude  any  damages.  During  the  transport  it  is  needed  to  use  the  proper 
equipment,  it  is  necessary  to  carry  the  device  by  two  people.  In  case  of  any 
damages  please  fill  in  the  damage  report  in  presence  of  the  Supplier  or  the 
carrier.

1.3 

PACKAGE CONTEN

- air curtain
- operation and maintenance manual and warranty card
- assembly panel
- door sensor
- remote controller

1.4

USE

Air  curtains  are  widely  installed  at  the  entrances  of  supermarkets,  theaters, 
meeting  rooms,  hotels,  offices,  storages  etc.  They  can  reduce  penetration  of 
insects, outside dust, unconditioned air into a conditioned space by forcing an air 
stream over the entire entrance. In winter they prevent uncontrolled heat loss 
and  in  summer  they  prevent  heat  from  the  room  (see  figures).  However,  air 
curtains should not be used in corrosive environments for aluminum, copper and 
steel as well as in highly dusty environments (above 0,3 g/m³).The devices should 
also not be installed in rooms where they would be exposed to high humidity or 
direct contact with water. 

consumption [A]

For air-conditioned rooms, the steering wheel must be set at an angle of 0-15 
degrees towards the air-conditioned room (see figure).

SECURITY AGAINST INSECTS 

AND ODORS

HEATED ROOM

INSIDE

OUTSIDE

A CLIMATED ROOM

  ENG

 

     

 

TECHNICAL DATA

BACK

TECHNICAL DATA 

AERIS 100E-1P

AC100E1P

Product code

AERIS 150E-1P

AC150E1P

AERIS 200E-1P

AC200E1P

Heater power [kW]

Current 

Maximum airflow 

[m3/h]

Maximum air speed

 [m/s]

Power supply [V] / Frequency [Hz]

Maximum 

motor power[W]

Rated motor 

current [A]

C

lass of isolation /Protection degree IP [-]

Net weight [kg]

Noise 

[dB]

26,1

14,3

20

17,4

29,1

40,9

8,7

43,5

60,9

1200

1900

2800

1100

1700

2500

8,5

8,5

8,5

7,5

7,5

7,5

230/50

230/50

230/50

15,5

20,5

26

57

59

61

55

57

59

E/IP20

E/IP20

E/IP20

III HEATING LEVEL

II HEATING LEVEL

I HEATING LEVEL

III HEATING LEVEL

II HEATING LEVEL

I HEATING LEVEL

6,0

3,3

4,6

4,0

6,7

9,4

2,0

10

14

I STAGE

II STAGE

I STAGE

II STAGE

I STAGE

II STAGE

I STAGE

II STAGE

I STAGE

II STAGE

180

230

350

130

180

300

2.2.TECHNICAL DATA

REVENTON GROUP 

AERIS 100E-1P

REVENTON GROUP 

AERIS 150E-1P

REVENTON GROUP 

AERIS 200E-1P

90 

105 

195 

265 

N. W. 

(kg)

15,5

20,5

26

INSIDE

OUTSIDE

INSIDE

OUTSIDE

consumption [A]

0,78

1,00

1,52

0,57

0,78

1,3