SAFETY INSTRUCTIONS AND WARNINGS 

 

Do not attempt to use this bathing system without first understanding this manual. 

To ensure safe operation, carefully read this entire manual, especially the section on "Safety Instructions and Warnings", 
before installing, operating, or servicing this equipment. 
 
If anything is not completely understood, please contact  Reval for more details. 
Failure to comply with warnings in this manual may result in injury. 
Keep this manual with the tub and refer to it as required. Contents of this manual are subjected to change without prior 
notice to users. 
 

 

The Bagheera bathing system must be installed by a contractor or a certified installation technician.  

 

 

DO NOT try to lift the tub. 

 

DO NOT place limbs or lay underneath the tub during lowering function. 

 

DO NOT operate the air whirlpool pump without water. 

 

DO NOT pull on the shower head too forcibly. 

 

DO NOT immerse the shower handset in water. 

 

DO NOT place any object underneath the tub. 

 

DO NOT adjust the water temperature over 43°C in the presence of patient. 

 

DO NOT use any electrical appliances near the tub. 

 

DO NOT use any electrical appliances (hair dryer or electric razor, …) while in the tub. 

 

DO NOT force controls or taps. 

 

DO NOT use or turn the disinfection shower on the patient.

 

 

ALWAYS perform a daily check before using the bathing system. 

 

Each client should be assessed for his or her ambulatory capability to ensure the clients safety when entering and 

       exiting the bathing system. (Ability to utilize handgrips, correct entry height, etc.) 

 

ALWAYS be prepared before transferring a patient into the tub. 

 

ALWAYS check the water temperature before the patient enters the tub or to use the cleaning shower. 

 

Clean bathtub after each use. 

 

Disinfect bathtub between each use. 

 

All valves should be closed after bathing is completed. 

 

When using disinfectant, wear rubber gloves and eye protection. In case of eye or skin contact, follow the

 

      procedures on the disinfectant container.

 

 

A weekly safety check should be performed to ensure all hoses, pipes, connections and securing devices 

      are in safe working order.  

 

Keep all tub components clean and dry. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

5/16 

Summary of Contents for BAGHEERA 7601.01

Page 1: ...EN Instruction manual Electric Hi Lo Bathtub BAGHEERA 7601 01 control panel on the right side 7601 02 control panel on the left side...

Page 2: ...TH FILL 8 CLEANING SHOWER HANDSET 8 DISINFECTION SHOWER HANDSET 8 DISINFECTION SYSTEM 9 AIR WHIRLPOOL IN OPTION 10 CHROMOTHERAPY IN OPTION 10 AROMATHERAPY IN OPTION 11 AUDIO SPA IN OPTION 12 INITIALIS...

Page 3: ...gh the handgrip Door to access to the 2L tank of disinfectant Disinfection shower Pump whirlpool option to the Rada Sense mixer Door to access Control panel Draining plughole whirlpool option Control...

Page 4: ...DIMENSIONS 37cm 13 5cm 82cm 19 209cm 48cm 51cm 28cm 85cm 153cm 103cm 63cm 185cm 55cm 7601 02 7601 01 3 16...

Page 5: ...7601 01 02 and 1150W with whirlpool option Pump of air whirlpool 230V 50hz 500W heater 250W PLUMBING Rada Sense bath shower concealed digital mixing valve offering programmable max min default tempera...

Page 6: ...ub DO NOT adjust the water temperature over 43 C in the presence of patient DO NOT use any electrical appliances near the tub DO NOT use any electrical appliances hair dryer or electric razor while in...

Page 7: ...he control panel ANTI CRUSHING DEVICE If an object or the foot of a user is by inadvertence between the blue frame foot and the bathtub and that the bathtub goes down the object or the foot of the use...

Page 8: ...perature of bath is pre set at 40 C The max temperature of cleaning shower is pre set at 38 C Automatic stop filling after few minutes for desired height of water Automatic stop of the cleaning shower...

Page 9: ...ing slightly the turn valve located at the end of the hose DISINFECTION SHOWER HANDSET The disinfection shower is identified thanks to a red label disinfection shower and a yellow flexible The disinfe...

Page 10: ...on The mixing of water and disinfectant inside the disinfection shower is made in 2 stages First Manual dilution inside the tank Second The suction device venturi ensures a dosage of 10 of the aspirat...

Page 11: ...eed and increase gradually to High Speed within half a minute Then it continues running 4 or 5 minutes at High Speed CHROMOTHERAPY IN OPTION The chromotherapy option consists of 4 LED lamps and 1 cont...

Page 12: ...omatherapy system on via the circular control panel Once up to temperature the heated air infuses with the aroma oil and releases its fragrance into the water via the diffuser jets positioned in the b...

Page 13: ...e or music device 3 On your music device click search for Bluetooth device Make sure you are close enough to the amplifier 4 Select PPGME60 from the pairing list 5 Enter 6000 as the password if requir...

Page 14: ...ler at the level of the foot of the bathtub At the end of about ten seconds the beep changes and becomes intermittent At this moment press alternately on a button then on the other one to activate eve...

Page 15: ...h should be retained by the person s responsible for the servicing maintenance of the bathtub The date when corrective actions are taken in response to noted observations should also be noted in the l...

Page 16: ...he filter out 4 Clean the filter in case of calcareous deposit use the appropriate scaler and rinse with clean water 5 Reassemble the parts CLEANING OF THE AIR WHIRLPOOL SYSTEM For the efficient funct...

Page 17: ...MAINTENANCE FORM LOGBOOK Agent name and signature Corrections Observations Tests Hi Lo tub Safety parts anti crushing device Control date 16 16...

Page 18: ...ulle Tel 33 05 46 42 04 16 Fax 33 05 46 43 06 38 www groupe reval com UNITED KINGDOM Reval Continuing Care Limited Unit 17 Brynmenyn Busines Centre St Theodore s Way Brynmenyn CF32 9TZ BRIDGEND WALES...