background image

 

DIRECTIONS FOR USE

 

 
 

BATH FILL 

 
 

Pass your hand in front of the sensor touch to start filling 
of the tub. 
The filling stops automatically when the water reaches 
the stainless steel support rail. 
 
It is possible at any time to stop the filling by passing 
your hand in front of the sensor.

 

 

 
 

CLEANING SHOWER HANDSET 

 

Check, water temperature, before each use. 

 

Pass your hand in front of the sensor touch to feed the 
hand shower. 
The hand shower is equipped with a trigger. 
 
For security reasons the water feeding will be cut off 
automatically after 5 minutes of operation. 
 
It is possible at any time to stop or restart the power of the 
hand shower by passing your hand in front of the sensor.

 

 

It is possible to adjust the pressure of the hand shower by closing or opening slightly the ¼ turn valve located at the end of 
the hose. 

 
 

DISINFECTION SHOWER HANDSET 

 

The disinfection shower is identified thanks to a red label "disinfection shower" and a 
yellow flexible. 
The disinfection shower allows the disinfection of the bathtub after each use and is 
connected to a disinfectant tank (see: disinfection system). The disinfectant product is 
sucked automatically pressing on the pawl.  
The disinfection shower is fed with cold water for a better effectiveness of the disinfectant 
product. 

A ¼ turn valve regulates the flow rate and cuts off the supply of the hand shower. 
 
 

 

After using the shower, do not forget to turn off the 1/4 turn stopcock.  

(a shower under pressure being much more fragile). 

 

Do not use the disinfection shower on the patient. 

 

Wait in order to respect the action time prescribed in accordance with the disinfectant used. 

15 minutes for the BFR4.0 disinfectant 

 

Rinse the tub with the cleaning shower after disinfection. 

 
 

8/16 

 

 

 

 

 

Summary of Contents for BAGHEERA 7601.01

Page 1: ...EN Instruction manual Electric Hi Lo Bathtub BAGHEERA 7601 01 control panel on the right side 7601 02 control panel on the left side...

Page 2: ...TH FILL 8 CLEANING SHOWER HANDSET 8 DISINFECTION SHOWER HANDSET 8 DISINFECTION SYSTEM 9 AIR WHIRLPOOL IN OPTION 10 CHROMOTHERAPY IN OPTION 10 AROMATHERAPY IN OPTION 11 AUDIO SPA IN OPTION 12 INITIALIS...

Page 3: ...gh the handgrip Door to access to the 2L tank of disinfectant Disinfection shower Pump whirlpool option to the Rada Sense mixer Door to access Control panel Draining plughole whirlpool option Control...

Page 4: ...DIMENSIONS 37cm 13 5cm 82cm 19 209cm 48cm 51cm 28cm 85cm 153cm 103cm 63cm 185cm 55cm 7601 02 7601 01 3 16...

Page 5: ...7601 01 02 and 1150W with whirlpool option Pump of air whirlpool 230V 50hz 500W heater 250W PLUMBING Rada Sense bath shower concealed digital mixing valve offering programmable max min default tempera...

Page 6: ...ub DO NOT adjust the water temperature over 43 C in the presence of patient DO NOT use any electrical appliances near the tub DO NOT use any electrical appliances hair dryer or electric razor while in...

Page 7: ...he control panel ANTI CRUSHING DEVICE If an object or the foot of a user is by inadvertence between the blue frame foot and the bathtub and that the bathtub goes down the object or the foot of the use...

Page 8: ...perature of bath is pre set at 40 C The max temperature of cleaning shower is pre set at 38 C Automatic stop filling after few minutes for desired height of water Automatic stop of the cleaning shower...

Page 9: ...ing slightly the turn valve located at the end of the hose DISINFECTION SHOWER HANDSET The disinfection shower is identified thanks to a red label disinfection shower and a yellow flexible The disinfe...

Page 10: ...on The mixing of water and disinfectant inside the disinfection shower is made in 2 stages First Manual dilution inside the tank Second The suction device venturi ensures a dosage of 10 of the aspirat...

Page 11: ...eed and increase gradually to High Speed within half a minute Then it continues running 4 or 5 minutes at High Speed CHROMOTHERAPY IN OPTION The chromotherapy option consists of 4 LED lamps and 1 cont...

Page 12: ...omatherapy system on via the circular control panel Once up to temperature the heated air infuses with the aroma oil and releases its fragrance into the water via the diffuser jets positioned in the b...

Page 13: ...e or music device 3 On your music device click search for Bluetooth device Make sure you are close enough to the amplifier 4 Select PPGME60 from the pairing list 5 Enter 6000 as the password if requir...

Page 14: ...ler at the level of the foot of the bathtub At the end of about ten seconds the beep changes and becomes intermittent At this moment press alternately on a button then on the other one to activate eve...

Page 15: ...h should be retained by the person s responsible for the servicing maintenance of the bathtub The date when corrective actions are taken in response to noted observations should also be noted in the l...

Page 16: ...he filter out 4 Clean the filter in case of calcareous deposit use the appropriate scaler and rinse with clean water 5 Reassemble the parts CLEANING OF THE AIR WHIRLPOOL SYSTEM For the efficient funct...

Page 17: ...MAINTENANCE FORM LOGBOOK Agent name and signature Corrections Observations Tests Hi Lo tub Safety parts anti crushing device Control date 16 16...

Page 18: ...ulle Tel 33 05 46 42 04 16 Fax 33 05 46 43 06 38 www groupe reval com UNITED KINGDOM Reval Continuing Care Limited Unit 17 Brynmenyn Busines Centre St Theodore s Way Brynmenyn CF32 9TZ BRIDGEND WALES...