SuperCleanox Operating instructions
Page
25
of 62
13.2 Automatic circuit breaker (overload FUSE)
The "SuperCleanox" is equipped with an automatic circuit breaker.
In the event of overload or an electrical short circuit, the circuit
breaker interrupts the circuit.
Safety information
Wait a moment until the circuit breaker has cooled down.
Before activating the circuit breaker button:
The appliance
must
be switched off.
The selector
must
be turned to position "0".
There must be no contact between the brush and the workpiece or earth.
If the circuit breaker is triggered again:
Check the way you are working!
Dip the brush more often into the wide-mouth container
--> Cool it!
Do not press the brush too hard against the workpiece!
13.3 High-current combo jacks
The "SuperCleanox" is equipped with high-current
combo jacks
red
/
black
for safely transmitting the
cleaning current.
These accommodate:
High-current plug
black
with 10/16mm² cable
only for cleaning and polishing with carbon
fibre brush.
4mm safety plug
black
with 1.5mm² cable
only for marking, cleaning and polishing with felt.
High-current plug
red
with 10/16mm² cable.
only
to connect the earth clip.
4mm safety plug
red
with 1.5mm² cable.
only
for connecting the earth clip for marking,
cleaning and polishing with felt.
Note
The 10/16mm² high-current plugs lock and can only be
released by gently pressing inwards.
The 1.5mm² safety plug does not lock.
Press the safety button
back into the housing to
activate
Circuit
breaker
triggered
by
overload.
The safety button jumps out of the
housing.
2
1
High-current jack
red
2
High-current jack
black
3
High-current plug / safety plug
red
4
High-current plug / safety plug
black
1
4
Marking/
cleaning
tools
Earth
connection
3
!!!