Page 54 of 91
© Retrotec 2017
Figure 63: Disable [Network] connection if using USB connection to a computer
[Settings]
[Network]
[Status]
must be set to “Disabled” if the gauge will be connect
ed to the computer
with a USB cable, since this direct connection does not involve a network. When [Network] is
“D
isabled
”
,
the gauge will not show a network connection icon on the
Home
screen.
Communication between a gauge and computer over USB connection requires the
installed on the computer that is to connect to the gauge(s). This driver is installed automatically when the
DM32 Software Suite
, any of the individual Retrotec software, or a new version of
FanTestic
is installed.
To update the firmware version on the gauge,
it is mandatory to connect via USB and use the DM32
Configurator software
, (i.e., updating firmware version on the gauge will not work if connected via an
Ethernet Cable).
It is possible, but not recommended to connect the gauge to a computer via USB and use “
FanTestic
” or the
“
Virtual Gauge
” software to control its functions.
Normally, the gauge should be connected to a computer
using the “Network” port and an Ethernet cable
since this form of connection is more stable, less
susceptible to interference, and can run longer distances.
Retrotec software (
FanTestic, Virtual Gauge, Data Logger
) should be able to detect the gauge(s) shortly
after they are connected to the computer via USB.