CONNECTION DIAGRAM
Caution! Voltage of heating elements 230V
Caution! ln the event of any connection
the earth wire must be connected to thePE terminal
Recommended
type of connection
lead
1
For 230 V earthed one-phase
connection, bridges connect 1-
2-3 terminals and 4-5
terminals,earth wire to .
H05VV-F3G4
2 For 400/230V earthed two-
phase connection, bridges
connect 2-3 terminals and 4-5
terminals, the earth wire to.
H05VV-F4G2.5
3 For 400-230V earthed two-
phase connection, bridges
connect 4-5 terminals, phases
in succession 1,2 and
3,Neutral to 4-5,the earth wire
to .
H05VV-F5G1.5
L1=R,L2=S,L3=T,N=neutral wire terminal, PE= earth wire terminal
Caution!
HOB Electrical connection
The hob to work with 230V alternating current, electrical connection must get the power
from the oven. Remember that the connection should match the same aspect.
1
2
3
4
5
L1
1
2
3
4
5
N
PE
L1
1
2
3
4
5
N
PE
L2
L1
1
2
3
4
5
N
PE
L2
L3
Summary of Contents for DIGI SET 8 GLAS PP