1. The extracted air must not be conducted by an exhaust pipe of a heater or similar, not
electrically-operated appliances.
2. Run the appliance with inserted grease filters only. Otherwise recirculating-
transported fat will deposit in the appliance and the exhaust system.
3. Constant cleaning and maintenance grants perfect function and best performance of
your appliance.
4.
Whenever you use extractor hoods in combination with non electrically-
operated appliances ( gas and oil-fired appliances ) , the negative pressure of
the corresponding room must not be more than 4 Pa ( 4 * 10
-5
bar ).
In this
particular case we recommend you install a window control switch or an air pressure
control device.
5. The relevant room must be well-ventilated.
6. Clean the appliance regularly.
7. Clean or replace the grease filters regularly.
1. The extracted air is conducted by an exhaust hose. You need an exhaust duct or an
exhaust pipe, which conduct the extracted air outside your home.
2. Whenever the hood is run in company with chimney-conducted firing ( e.g. coal
furnace ), ensure there is sufficient air supply to the room where the appliance is
installed.
3.
Regulations concerning the discharge of air have to be fulfilled.
4. If there is not a stationary exhaust pipe or an exhaust duct, you must convert your
appliance to recirculating mode.
Always consult your local chimney-sweep master
.
1. The extracted air runs through a carbon filter ( also named active carbon filter ) back
into the room. The carbon filter extracts the odours produced by cooking.
2. The fresh air is leaded back by air outlets on the sides or on the back of the
appliance.
3. When you run the appliance in the recirculating mode, you can simultaneously run
room-air dependent fireplaces.
1. This appliance is designed for the use by adults only. Children must neither play
around nor play with the appliance.
2. Do not use the appliance for camping.
3. Do not use the appliance in public transport.
4. The appliance is designed for indoor use only.
Final safety instructions
Special measures
extraction mode
Special measures
recirculating mode
7