background image

The Alarm will emit a short beep and flash the 

Yellow LED when it becomes partially depleted. 

Check the date when the Alarm should be 

replaced which is given on the sidewall of the 

Alarm. When electronic self testing indicates 

that the battery is becoming low the Alarm will 

beep and the yellow LED will flash at the same 

time (about every 48 seconds) to warn the 

user. This indicates that the battery or batteries 

must be replaced.

1.2.2. Contaminated chamber
If the Alarm sounds without any apparent 

smoke being present, press the test button to 

silence the Alarm for 10 minutes (as described 

in 1.1.5 above). If the Alarm sounds again 

it may be contaminated. Pressing the test 

button again, within 4 minutes of the Alarm 

re-sounding, will get the Alarm to compensate 

for chamber contamination. This will normally 

resolve the problem.
If the Alarm re-sounds for a third time, the 

Alarm is excessively contaminated and must 

be replaced. If it is not convenient to replace 

it immediately, pressing the test button within 

4 minutes of it going into alarm (for the third 

time) will silence the Alarm for 8 hours – 

however it will give two short beeps (second 

apart) every 10 minutes to remind the user it 

has been disabled. If the contamination clears 

the Alarm will return to normal operation.
(Note: this does not reduce the users fire 

protection, as a Smoke Alarm in continuous 

alarm due to a fault, is useless and must be 

silenced – by taking the Alarm down or as 

described here. This procedure has the added 

Indicator Summary

Normal Operation

Action

Red LED

Yellow LED

Sounder

Power Up

Insert Battery

1 Flash

1 Flash

Off

Standby

Off

Off

Off

Sensing Fire

Rapid Flashing

Off

Full Sound

Fault Mode

Action

Red LED

Yellow LED

Sounder

Low Battery

Off

1 Flash every 48 sec

1 Beep

Faulty Smoke Sensor

Off

2 Flashes every 48 sec

2 Beeps

Faulty Heat Sensor 

Off

2 Flashes every 48 sec

2 Beeps

End of Life

Off

3 Flashes every 48 sec

3 Beeps

Silence Sounding 
Alarm

Press & Release Button

1 Flash every 8 sec

Off

Off for 10 mins

Silence “End of Life” 
indication (up to 
30 days)

Press & Release Button

Off

Off for 72 hours

Off for 72 hours

Test Mode

Action

Red LED

Yellow LED

Sounder

Test Smoke Alarm

Press Button

Rapid Flashing

Off

Full Sound

Alarm Memory

Action

Red Led

Yellow LED

Sounder

24 Hour Memory

2 Flashes every 48 
sec for 24 hours

Off

Off

Long Term Memory

Press & Hold Button

Rapid Flashing

Off

Rapid Chirping

1.1. Normal Operation

1.1.1. Power Up
Twist off the Alarm from the mounting plate 

(see Quick Start Guide). Remove the battery 

tab to power the Alarm, the red LED will flash 

once followed by one flash of the yellow LED 

to indicate that the Alarm has been powered 

successfully and is now in standby mode.
1.1.2. Standby
In standby mode there are no active visible or 

audible indications which can be intrusive to 

the householder. To confirm that the Alarm is 

operational perform a weekly button test.
1.1.3. Weekly button test
Press and hold the test button and verify that 

the red LED flashes rapidly and the Alarm 

ramps up to full sound.
1.1.4. Sensing Fire
As soon as the Alarm senses smoke it will 

go into Alarm. The red LED on the Alarm 

sensing smoke flashes rapidly to indicate this 

is the Alarm sensing smoke / fire. Follow the 

instruction in section 3 and evacuate the 

building.
1.1.5. Silence False / Nuisance alarm
Occasionally Smoke Alarms can be activated 

by phenomena other than fire, e.g. dust, 

insects, cooking fumes. Once you are sure it is 

a nuisance alarm press the large test button to 

silence the Alarm for 10 minutes – the red LED 

will then flash every 8 seconds for 10 minutes.

1.2. Fault Conditions

1.2.1. Low battery

2

Summary of Contents for RE314 DSC

Page 1: ...mode and then holding down the smoke s test button until the smoke alarm beeps 5 Remove the mounting plate and refer to Sections 2 and 6 for positioning and installation 6 After mounting plate is inst...

Page 2: ...ED Sounder Low Battery Off 1 Flash every 48 sec 1 Beep Faulty Smoke Sensor Off 2 Flashes every 48 sec 2 Beeps Faulty Heat Sensor Off 2 Flashes every 48 sec 2 Beeps End of Life Off 3 Flashes every 48 s...

Page 3: ...tors The installation of smoke detectors in kitchens attics finished or unfinished or garages is not normally recommended as these locations occasionally experience conditions that can result in impro...

Page 4: ...ALARMS 610mm 24 FROM APEX DEAD AIR SPACE Wall Mounting If ceiling mounting is impractical Smoke Alarms may be mounted on a wall provided that a the top of the detection element is between 150mm 6 and...

Page 5: ...e quickly silenced by fanning vigorously with a newspaper or similar to remove the smoke or press the test hush button Do not attempt to recharge or burn the battery as it may explode If it is necessa...

Page 6: ...nsurance The supplier or manufacturer is not your insurer Fire Safety Hints Store petrol and other flammable materials in proper containers Discard oily or flammable rags Always use a metal fireplace...

Page 7: ...ng Maintenance and Power Supply Monitoring then contact Customer Assistance at the nearest address given at the end of this leaflet If it needs to be returned for repair or replacement put it in a pad...

Page 8: ...l other Alarms in the system WARNING Do not test with flame This can set fire to the Alarm and damage the house We do not recommend testing with smoke as the results can be misleading unless special a...

Page 9: ...ery 8 seconds to indicate that the unit has been silenced 2 The Smoke Alarm will reset to normal sensitivity at the end of the silenced period 10 minutes If additional silenced time is required simply...

Page 10: ...sects or cobwebs in the vicinity of the Smoke Alarm should be promptly removed In certain circumstances even with regular cleaning contamination can build up in the smoke sensing chamber causing the A...

Page 11: ...larm fails to sound when the Test button is pressed Check the age of the unit see the replace by label on side of unit If necessary replace the battery or batteries with Panasonic CR123A 9 System Comp...

Page 12: ...ice may not cause interference and 2 This device must accept any interference including interference that may cause undesired operation of the device Le pr sent appareil est conforme aux cnr d Industr...