1. SAFETY
2. INTRODUCTION
4. MOUNTING
3. bATTERIES
1.1.
This alarm is a smoke detector of the photo cell principle. This means that the alarm checks the air for smoke resulting from fire. It does
not detect heat, gas or fire.
1.2.
If the smoke detector is properly mounted and maintained it will sound an alarm at an early stage. In the event of a fire it can give you
those extra seconds needed to vacate your home and call the fire brigade.
1.3.
The alarm is designed to detect smoke, it can not prevent a fire.
1.4.
Placing a smoke alarm is part of your fire protection, just as: fire extinguishers, emergency ladders, ropes, choice of materials used in
renovation are.
1.5.
Always ensure that you have an evacuation plan, and discuss this with your children. Ensure that each room can be left without opening
the door, e.g. by the window. If there is any question as to the cause of an alarm, it should be assumed that the cause is an actual fire
and the dwelling evacuated immediately.
1.6.
DO NOT
paint the smoke alarm.
3.1.
The smoke detector works on one 9V DC battery. Normally the battery will last at least one year under normal conditions of use.
3.2.
If the battery is flat or almost flat the smoke detector will indicate this with an audible “beep”. This indicator sounds continually with
intervals of 30-40 seconds for at least 7 days.
3.3.
Replace the battery when this indicator sounds. Use a 9V alkaline DC battery of high quality.
3.4.
battery Replacement
3.4.1. Turn the alarm anticlockwise to remove it from the baseplate. Remove battery and replace ensuring connector is fitted securely. Refit
to baseplate.
4.1.
Where is the best place to mount smoke detectors?
•
at least one in each room
• in the hallway, in the stairway
• in front of each bedroom door
• in each bedroom (if you sleep with door shut)
• in the living room
• in a storage room or spaces with electric equipment
4.2.
The smoke alarm should not be mounted in:
• a room in which the temperature can reach below -4°C or above 40°C
• in damp spaces
• just in front of doors or windows and not near a ventilator or radiator
4.3. DO NOT
mount the alarm in a place which is difficult to reach because of the need to reach the test button, to replace the battery and
carry out maintenance.
4.4. Mounting
4.4.1. mount the alarm in the centre of the ceiling of the room.
4.4.2. Fix the base plate, using the screws provided, onto the area chosen. Refer to fig.1.
4.4.3. Gently tighten the alarm onto the base plate.
Manufactured according to CE standards. Detachable composite facia, allowing the user to change the 9V battery (not included) when
required. Test function enables the operator to test the alarm and to help distinguish the alarm sound.
fig.1