background image

11

• Press the Test/Silence button on the Smoke 
Alarm causing the Alarm (this can be identified 
as the Alarm with the red light flashing 
rapidly) – this will silence the Smoke Alarm 
for 10 minutes (and also silence all other 
interconnected Alarms in the system).

The Alarm fails to sound when the Test 

button is pressed

• Check the age of the unit - see the “replace 
by” label on side of unit.
• If necessary replace the battery or batteries 
with Panasonic CR123A. 

9. System Compatibility and 

Wireless Verification

Smoke alarm model RE314 has only been 
evaluated at ETL with DSC Impassa Model#: 
SCW9057.

Test the system after finishing installation, 
enrollment, and configuration.  Refer the 
panel’s manual for instructions on testing the 
system.

Summary of Contents for RE314 DSC

Page 1: ...mode and then holding down the smoke s test button until the smoke alarm beeps 5 Remove the mounting plate and refer to Sections 2 and 6 for positioning and installation 6 After mounting plate is inst...

Page 2: ...ED Sounder Low Battery Off 1 Flash every 48 sec 1 Beep Faulty Smoke Sensor Off 2 Flashes every 48 sec 2 Beeps Faulty Heat Sensor Off 2 Flashes every 48 sec 2 Beeps End of Life Off 3 Flashes every 48 s...

Page 3: ...tors The installation of smoke detectors in kitchens attics finished or unfinished or garages is not normally recommended as these locations occasionally experience conditions that can result in impro...

Page 4: ...ALARMS 610mm 24 FROM APEX DEAD AIR SPACE Wall Mounting If ceiling mounting is impractical Smoke Alarms may be mounted on a wall provided that a the top of the detection element is between 150mm 6 and...

Page 5: ...e quickly silenced by fanning vigorously with a newspaper or similar to remove the smoke or press the test hush button Do not attempt to recharge or burn the battery as it may explode If it is necessa...

Page 6: ...nsurance The supplier or manufacturer is not your insurer Fire Safety Hints Store petrol and other flammable materials in proper containers Discard oily or flammable rags Always use a metal fireplace...

Page 7: ...ng Maintenance and Power Supply Monitoring then contact Customer Assistance at the nearest address given at the end of this leaflet If it needs to be returned for repair or replacement put it in a pad...

Page 8: ...l other Alarms in the system WARNING Do not test with flame This can set fire to the Alarm and damage the house We do not recommend testing with smoke as the results can be misleading unless special a...

Page 9: ...ery 8 seconds to indicate that the unit has been silenced 2 The Smoke Alarm will reset to normal sensitivity at the end of the silenced period 10 minutes If additional silenced time is required simply...

Page 10: ...sects or cobwebs in the vicinity of the Smoke Alarm should be promptly removed In certain circumstances even with regular cleaning contamination can build up in the smoke sensing chamber causing the A...

Page 11: ...larm fails to sound when the Test button is pressed Check the age of the unit see the replace by label on side of unit If necessary replace the battery or batteries with Panasonic CR123A 9 System Comp...

Page 12: ...ice may not cause interference and 2 This device must accept any interference including interference that may cause undesired operation of the device Le pr sent appareil est conforme aux cnr d Industr...

Reviews: