When a function is selected, a submenu will open in which all adjustments required
can be made.
When a function has been adjusted and saved, it will appear in the Opt. functions
menu above the menu item Add new function.
This allows an easy overview of functions already activated.
At the end of each optional function submenu, the menu items Function and Save
function are available.
In order to save a function, select Save function and confirm the security enquiry
by selecting Yes. In functions already saved, the menu item Delete function will
appear instead.
In order to delete a function already saved, select Delete function and confirm
the security enquiry by selecting Yes.
If the menu item Delete function is confirmed by pressing the right button (
✓
), a
security enquiry appears. The setting can be changed between Yes and No by turning
the Lightwheel
®
. If Yes has been selected and confirmed by pressing the right button
(
✓
), the function is deleted and available under Add new function again.
With the menu item Function, an optional function already saved can be temporarily
deactivated or re-activated respectively. In this case, all adjustments remain stored, the
allocated relays remain occupied and cannot be allocated to another function.
Internal backup heating
Opt. functions / Add new function / Backup heat.int.
Adjustment channel Description
Adjustment range / selection Factory setting
Sensor
Reference sensor
S1 … S3
S1
Ton
Switch-on temperature
20 … 74 °C
40 °C
Toff
Switch-off temperature
21 … 75 °C
45 °C
Timer
Timer option
Yes, No
No
Funct.
Activation / Deactivation Activated, Deactivated
Activated
Save function / De-
lete function
Save / Delete function
-
-
The internal backup heating function is used for operating the electric heating
for backup heating with current from the mains. For this purpose, the power stage
is switched on. The switch-on and switch-off temperatures Ton and Toff are used
as reference parameters.
If the temperature falls below the adjusted threshold Ton, the power stage and the
relay switch on. They switch off, if the temperature exceeds Toff.
The reference sensor is selectable. If the maximum temperature is exceeded at S1,
the backup heating is interrupted. Upon saving the function, the note Use of mains
current possible! appears.