background image

A0

No.59,Liantang Road,Sanzhongcun,Qingxi Town,
Dongguan,Guangdong,China,523651
Tel: 

86- 769- 87841199

Tmall: 

reptizoo.tmall.com

Overseas Sales: 

[email protected]

China Sales: 

[email protected]

www.repti-zoo.com

Dongguan ETAN Pet Supplies Co.,Ltd.

Summary of Contents for THC16

Page 1: ...LLER INSTRUCTION MANUAL Thanks for choosing REPTIZOO EZ thermostat timer controller In order to use this EZ thermostat timer controller properly and ensure its service life please read the instructions manual carefully before using it ...

Page 2: ...nd multi time period timing control a maximum of four periods It provides power control for heating cooling timing devices in reptile pet and aquarium pet feeding garden building etc It is an excellent intelligent management product in reptile pet feeding industry Thank you for choosing the products of REPTIZOO Please read this Manual carefully and follow the instructions before operation PRODUCT ...

Page 3: ...y temperature control setting value DESCRIPTION OF THE OPERATION INTERFACE OF THE CONTROL BOX AND POWER OUTPUT BOX 1 Description of the control box panel 2 Description of controller panel and LCD 6 7 8 The over temperature alarm function can intuitively show the discomforts of pets arising from the temperature being too high or too low thus to better protect your pet Relying on the power failure m...

Page 4: ...or T SENSOR indicates the temperature sensor It can be mounted by aligning the male and female bus to the slots and pressing hardly TECHNICAL PARAMETERS AND DESCRIPTION 1 Description of the major parameters Control box size 160x50x23 mm Power output box size 195x77x50 mm Working voltage 120V 60Hz Temperature control range 32 122 F Temperature measurement range 4 122 F Temperature difference settin...

Page 5: ...rload protection function With power failure memory function The sensor detection frequency is once per every 5 seconds 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Day on Night on Day temperature on Day temperature off Night temperature on Night temperature off T Timer 1 ON T Timer 1 OFF T Timer 2 ON T Timer 2 OFF T Timer 3 ON T Timer 3 OFF T Timer 4 ON T Timer 4 OFF Starting time of day Starting time of nig...

Page 6: ...perature with the day temperature controller or the night temperature controller If the current temperature is the power on temperature start way A power output and the heating lamp will start working Conversely if the temperature is the power off temperature stop way A power output and the heating lamp will stop working Operation description of the device at way B UV lamp Set the time by timer A ...

Page 7: ...ters DESERT parameters and description 2 Advanced user user defining Settings of current time day and night starting time Press the Time button in sequence and the corresponding hours minutes corresponding to current time day starting time and night starting time will flash on the LCD in sequence When the number is flashing you can adjust it by pressing or increasing or decreasing by 1 each time L...

Page 8: ...ue to frequent startup in a short time When the first value is less than the second value under the symbols and it means heating mode Day and night temperature setting Press the and in sequence The corresponding day temperature and night temperature will flash in sequence on the LCD When the number is flashing you can adjust it by pressing or increasing or decreasing by 1 each time Long press to i...

Page 9: ...the power off time of time period 3 will be T6 the power on time of time period 4 will be T7 and the power off time of time period 4 will be T8 Then when we set the values we must make sure that T1 T2 T3 T4 T5 T6 T7 T8 The setting method of power on and power off time of time period 2 3 and 4 is the same as above 00 00 00 23 59 59 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 23 5...

Page 10: ...evice from moisture or splashed water during use If any extension cord is used the extension cord should be of appropriate rating current and weather rating Place the wires with care to avoid being torn or pulled When toggling the power switch and plugging the power cord from the socket make sure your hands are dry Do not pull the cable out of the socket forcibly When the product is not in use unp...

Page 11: ... up If yes press to reset Reset to factory settings The fifth point below is how to set factory settings If all attempts fail replace the entire device 3 The temperature and temperature values are displayed as Check if there is any breakage damage or severe indentation on the sensor cable If yes please replace the sensor 4 Time powered battery It is recommended to replace the battery every six mon...

Page 12: ...nzhongcun Qingxi Town Dongguan Guangdong China 523651 Tel 86 769 87841199 Tmall reptizoo tmall com Overseas Sales postmaster repti zoo com China Sales market_one repti zoo com www repti zoo com Dongguan ETAN Pet Supplies Co Ltd ...

Reviews: