107
en
Healthbox
®
II (Compact) & Healthbox
®
Smartzone
Display: LED blinks SLOWLY
for 10 hours
after 10 hours, ECO-LED
will be on permanently
8.3 • Special control possibilities
8.3.1 • C-mode (= design mode)
System without demand control at nominal system pressure. All valves at nominal setting.
This mode can be used by the installer for an inspection of the flow per exhaust louvre (room).
eco
eco
eco
Action:
Press longer
Fan unit will fan for
10 hours
in Full Breeze Mode;
afterwards, EcoMode is
automatically switched on
eco
eco
eco
8.3.2 • Reset mode
Resets the fan unit.
Action: Simultaneous,
press longer (> 5 sec.)
Display after start-up:
LED burns permanently
Fan unit
restarts
eco
eco
Action: Simultaneous,
press longer (> 5 sec.)
Display:
4 LEDs 30 min. On
after 30 minutes, ECO-LED
will be on permanently
Fan unit will fan for
30 minutes
in C-Mode;
afterwards, Eco Mode
will automatically
switch on