background image

 

13 

maintenance / disposal

 

Servicing: 

-

 

Keep accumulated liquids below baffle on general purpose units and below element on oil 
removal units. 

-

 

Replace filter element when dirty or when service indicator (if so equipped) shows 
approximately one-half red / green 

 

Maintenance: 

WARNING!     

                                                                                                                                 

Risk of injury from using incorrect replacement valves!             

Using incorrect or faulty replacement valves may endanger personnel and cause 

damage, malfunctions, or total failure. 

 

Only use the manufacturer’s original replacement valves 

 

Contact the manufacutrer for information about replacement valves, see the 

manufacturers address on the rear of this booklet 

 

Disposal: 

 

CAUTION!     

                                                                                                                                 

Improper disposal may result in risks to the enviorment. 

 

 

At the end of their life have proportional pressure control valves disposed of by a licensed 

waste disposal contractor 

 

If in doubt, ask the local municipal authority or special waste disposal contractors for more 

information 

 

 

 

 

 

 

 

Summary of Contents for EP10000000R

Page 1: ...Electro pneumatic converter Assembly manual and operating instructions ENG...

Page 2: ...2 Renova certification Copyright Renova Srl 2013 All rights reserved...

Page 3: ...stance page 4 general information page 5 saefty page 5 protective equipment for personal page 7 technical data page 8 transport and storage page 9 installation page 9 function and tests page 12 mainte...

Page 4: ...ed and or any previous manuals warnings CAREFULLY READ THE INSTRUCTIONS AND WARNINGS IN THIS MANUAL AND KEEP THEM FOR FURTHER REFERENCE FOR THE ENTIRE LIFE OF THE PRODUCT IN THIS MANUAL ARE IMPORTANT...

Page 5: ...if not avoided CAUTION This combination of symbol and signal word indicates a possibly hazardous situation that may may result in damage to property of environmental damage if it is not avoided liabi...

Page 6: ...ed by lack of training People who lack propoer training cannot assess the risk when handling the proportional pressure control valves and they place others at risk of serious injury or death Have all...

Page 7: ...ainst contact heat and sharp objects Safety goggles protect the eyes from fl ying objects and splashing liquids Ear protection protects the ears from damage caused by exposure to noise Protective clot...

Page 8: ...500 ms from 0 to 100 or 150 ms from 100 to 0 of output pressure into a 10cc load Degree of protection Hysteresis and deadband IP20 1 of span Linearity 1 5 of span Vibration immunity 3 output shift for...

Page 9: ...cked units in the box they were shipped in Do not store them outdoors Store them in a dry dust free place Don t expose them to aggressive media such as salty air Protect them from direct sunlight Stor...

Page 10: ...valve Connect pipe work using 6mm or OD 4mm ID plastic pipe cut cleanly at right angles with push fit pipe connections or with suitable rigid piping WARNING Danger of injury caused by compressed air...

Page 11: ...nents can perform uncontrolled movements and result in serious injury Isolate the electrical supply before starting work and male sure it cannot be switched back on A qualified electrician and the fol...

Page 12: ...output pressure Cycle the unit from 0 100 for 10 cycles 2 Set control signal to 5 of full scale and monitor the output pressure at the unit ouput port using an accurate manometer Check the output is w...

Page 13: ...ment valves may endanger personnel and cause damage malfunctions or total failure Only use the manufacturer s original replacement valves Contact the manufacutrer for information about replacement val...

Page 14: ...14 Index of manual revision note Rev n Rev Date Description of the changes made...

Page 15: ...15...

Page 16: ...Renova srl viale Rimembranze 93 20099 Sesto San Giovanni MI Italy tel 39 02 2700 7394 fax 39 02 2570 8635 www renova srl com email support renova srl it...