21
Press SELECT until you highlight the Load Mode Screen where
it should demonstrate a numerical load mode. The following chart
indicates numbers representing hours ON that the load terminal
Programs 0, 1-14, 16, and 17 are automatic processes that
operate from the PV detection circuit as soon as they are set.
No other action is necessary. Program 15 requires manual user
toggling so users will need to press ENTER on the Main Screen
or Load Mode Screen to observe the Light Bulb Brightness icon
being activated to confirm Load also being activated.
Manual
Test
24Hr
In this mode, the user can turn the
Load On/Off by pressing the Enter
button at any time.
The load will be on for 24 hours a day.
Used to troubleshoot load terminal
(No Time Delay). When voltage is
detected load will be off and when no
voltage is detected load will be on.
15
16
17
Time
control
The load will turn on at night when the
solar panel is no longer producing
any power after a short time delay.
The load will turn off when the panel
starts producing power.
When the panel is no longer
producing power, the load will be ON
for 1-14 hours or until the panel starts
producing power.
Automatic
(On/Off)
Setting
Mode
Description
0
1-14
1.Highlight Load Mode Screen
2.Hold ENTER for approximately 3s until the Load Mode starts to flash
3.Tap SELECT to highlight your desired Load Mode
4.To confirm, hold ENTER for 3s to select your Load Mode