Model MMU-1600G Series Op Man - Ver 1.07.23 - Rev 20151026DL
Page 28 of 58
L
OGIC
I
NPUTS
:
CVM:
True .................... < +8 VDC
False .................... > +16 VDC
External Reset Input:
True .................... < +8 VDC
False .................... > +16 VDC
+24V Monitor Inhibit Input:
True .................... < +8 VDC
False .................... > +16 VDC
Port 1 Disable Input:
True .................... < +8 VDC
False .................... > +16 VDC
Type Select Input:
True .................... < +8 VDC
False .................... > +16 VDC
Local Flash Input:
True .................... < +8 VDC
False .................... > +16 VDC
External Watchdog Input:
True .................... < +8 VDC
False .................... > +16 VDC
R
ESET
: Meets and/or exceeds NEMA TS 2-2003 specifications. The monitor can be manually reset by depressing
the
RESET
pushbutton on the front panel.
3.3
TIMING FUNCTIONS
S
TART
D
ELAY
: ..................................................................................................................................... 2.0 sec (±0.5 sec)
M
INIMUM
F
LASH
:.............................................................................................................................. 6 to 16 sec (±1 sec)
P
ORT
1
F
AIL
:
Typical ............ 300 msec
F
IELD
C
HECK
F
AIL
:
Typical .......... 1000 msec
C
ONFLICT
:
No Fault ..... < 200 msec
Detect .........> 450 msec
Typical ............ 300 msec
R
ED
F
AIL
:
No Fault ..... < 700 msec
Detect .........> 1000 msec
Typical ............ 800 msec
CVM
F
AULT
:
No Fault ..... < 125 msec
Detect .........> 175 msec
Typical ............ 150 msec
+24
VDC
M
ONITOR
:
No Fault ..... < 125 msec
Detect .........> 175 msec
Typical ............ 150 msec
C
LEARANCE
F
AIL
:
No Fault ..... < 2.8 sec
Detect .........> 2.6 sec
Typical ................ 2.7 sec
D
UAL
I
NDICATION
:
No Fault ..... < 300 msec
Detect .........> 800 msec
Typical ............ 500 msec
MONITOR
P
OWER
F
AIL
:
Ignore ......... < 450 msec
Respond ......> 500 msec
Typical ............ 483 msec
F
LASHING
D
ON
’
T
W
ALK
:
Flashing if state changes are > 200 msec and < 600 msec
Typical ............ 500 msec
No Fault ..... < 1400 msec
Respond ......>1600 msec
Typical .......... 1500 msec