background image

4

Installation

GENERAL INORMATION

Your IC Live column array was designed to be easy to install on either a flat surface such as a wall. Note that it was not designed to be 

mounted in the wall or in an alcove. The amplifiers are convection cooled and their heat sinks require at least an inch of separation from 

the nearest surface. 

The included hinge kits allow wall mounted column arrays to be rotated 90 degrees away from the wall to provide easy access to the rear 

access ports during installation and for routine testing and service. They also provide the separation needed for cooling.

Installation should only be performed by skilled personnel who have thorough knowledge of the wall structure, wall materials and neces-

sary hardware for mounting the loudspeakers. 

 

WALL MOUNTING

The following instructions assume that the column array(s) will be mounted using the included Renkus-Heinz HK series hinge kits.

The hinge kits will be packed in one of the cartons.  Each mounting plate has hinges on both the right and left sides of the plate to provide 

for either “right” or “left” swing away from the wall. ICL-FRO-M columns will have two hinge sections; ICL-FRO-DUAL-M columns will have 

three hinge sections; ICL-FRO-TRIP-M columns will have four hinge sections. 

 

The female hinges are attached to the column and the male hinges to the wall. The photos below show the male mounting plates with pins 

in both positions for illustrative purposes. 

Notice that one of the wall mounting hinge plates has a metal strap attached to it. This is the hinge plate that goes on the bottom. The 

metal strap attaches to the bottom of the array after it is hung and is used to lock the column array in place.

 

Hint: To simplify the mounting many installers will first cut a “backing plate” the size of the

 

column out of heavy plywood and mount the hinge plates on it. It’s a lot easier to align the  

 

 

 

 

hinge sections on a piece of plywood than it is on the wall. Then, when the alignment is 

 

perfect they mount the “backing plate” to the wall.  After that, it’s usually a comparatively   

 

 

 

 

easy task to hang the column array on the backing plate. 

After the column array is hung on the wall, remove the machine screw from the center of the end cap with the restraining strap and use it to 

attach the strap. 

In outdoor or weatherized applications, the restraining strap should only be used on the bottom.

Summary of Contents for IC Live FRO Series

Page 1: ...Digitally Steerable Line Array Loudspeaker Systems ICL FRO M ICL FRO M WR ICL FRO DUAL M ICL FRO DUAL M WR ICL FRO TRIP M ICL FRO TRIP M WR FRO Series USERS MANUAL Installation Instructions IC Live...

Page 2: ...IONS ARE FOR USE BY QUALIFIED SERVICE PERSONNEL ONLY TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT PERFORM ANY SERVIC ING OTHER THAN THAT CONTAINED IN THE OPERATING INSTRUCTIONS UNLESS YOU ARE QUALIFIED...

Page 3: ...ON To reiterate the above warnings servicing instructions are for use by qualified personnel only To avoid electric shock do not perform any servicing other than that contained in the Ope ration Instr...

Page 4: ...wing away from the wall ICL FRO M columns will have two hinge sections ICL FRO DUAL M columns will have three hinge sections ICL FRO TRIP M columns will have four hinge sections The female hinges are...

Page 5: ...F3 TOOLS REQUIRED Drill 5 32 5 8 Drill bits Socket Driver 1 2 Socket Philips 2 screwdriver or socket driver INSTALLATION NOTE Each HK series hinge consists of two parts a male mounting plate and a fe...

Page 6: ...ched to Column Cabling Note When the loudspeaker position relative to its cable drop does not allow the conduit to enter from below the conduit must go down behind the loudspeaker and loop back up to...

Page 7: ...onnected changeover to Secondary is automatic if Primary fails Analog Inputs 1 2 Phoenix 6 pin connector ID Dipswitches Primary Secondary AES EBU Inputs ST connectors 240 V AC IEC Power Connector ACTI...

Page 8: ...19201 Cook Street Foothill Ranch CA USA Phone 1 949 588 9997 Fax 1 949 588 9514 sales renkus heinz com www renkus heinz com RH 814 Rev B August 2019...