•   The twilight switch can be mounted on a vertical wall via two openings (1). To do this,  

appropriate screws and, if necessary, plugs must be used.

 

   It is imperative that you pay attention to the correct installation position. On 

the rear of the twilight switch you will find an arrow symbol “

”. The arrow 

head must point vertically upwards, the cable grommets (6) downwards.

 

The twilight switch may only be mounted to the wall in this position!

   Pay attention when drilling and tightening the screws that no cables and pipes are 

damaged.

•   Pass the connection cables (mains cable and cable for consumer load) through the 

rubber seals (6). Cut the rubber seals only as far as necessary so that the connec-

tion cables can be passed through.  

•   Connect  the  connection  cables  (mains  cable 

and  cable  for  consumer  load)  with  the  terminal 

clamps (5). 

   For this purpose, observe the labels on the termi-

nal clamps and the wiring diagram.

   The terminal clamp “L1” is the switching output 

for the consumer load.

•   Once you have carried out the timer and brightness adjustment (see next section), 

place the front lid in the correct way. 

 

   The small, transparent, round opening of the front lid must located above the 

brightness sensor (2).

 

 Furthermore, pay attention that the seal outside in the bottom part is located 

correctly in the slot and the plastic cord between the front lid and bottom 

part is not pinched.

  Afterwards, tighten the 4 casing screws that you removed at the beginning.

Timer and brightness adjustment

•  Setting the switch-on time 

   Using the right control knob (3), you can set the switch-on time for the consumer 

load connected. 

  D-D  sunset until sunrise (switched off during the day)
  2H 

Switch-on time 2 hours

  4H 

Switch-on time 4 hours

  6H 

Switch-on time 6 hours

  8H 

Switch-on time 8 hours

•  Setting the brightness switching threshold 

  With the left rotary knob (7), the switching threshold can be set, from which the 

ambient brightness at which the twilight switch shall be activated.

   Turning the knob to the left in direction of the moon symbol activates the twilight 

switch only with great darkness, turning it to the right in direction of the sun symbol 

activates the twilight switch in brighter conditions. 

•  Setting the brightness switching threshold manually

   Using the countersunk push-button “M” (4) at the right edge of the twilight switch, 

the current brightness can be programmed as switching threshold.

  Impress the push button for more than 1 second to save the current brightness.

    If you turn the control knob (7), the manual switching threshold will be dele-

ted and the setting of the control dial will be applied.

Function test

If you want to perform a function test after installation, proceed as follows:
•   Move the right control knob (3) to the position “D-D” by turning it completely to the 

left in counter-clockwise direction.

•  The consumer load will not be switched on during daylight hours.
•   If you cover the brightness sensor, the connected consumer should be activated after  

approximately 10 seconds.

•   If you release the brightness sensor again, the consumer load will be switched off 

after 10 seconds.

Function/operation

•  Setting “D-D”:

   When the right control knob (3) is in the “D-D” position, the connected consumer 

load will be switched on at nightfall (depending on the adjustment of the brightness 

switching threshold) and switched off again with sufficient brightness in the mor-

ning. 

   In order to prevent a continuous switching on/off during short brightness changes, 

a time lag of 10 seconds has been provided. 

•  Setting “2H”, “4H”, “6H” or “8H”:

   Upon reaching the adjusted brightness switching threshold, the consumer load will 

be switched on for 2h, 4h, 6h or 8h and then switched off automatically. 

   Should any light fall on the brightness sensor for 10 minutes during this time period, 

the consumer load will be switched off (for example, a switched on street light or a 

car with lights switched on standing in front of the twilight switch). 

Maintenance and care

The twilight switch is maintenance free. For this reason, you should never open it or 

take it apart (except for the procedure for installation and connection described in 

this manual). Maintenance or repairs may only be performed by qualified personnel.
Clean the transparent lens of the brightness sensor occasionally with a soft clean and 

dry cloth. To remove more persistent stains, moisten the cloth with water.
Do not use any aggressive detergent as this might cause discolouration.

Disposal

   Dispose of an unserviceable product in accordance with the relevant statu-

tory regulations.

Technical data

Operating voltage............................... 220 - 240 V/AC, 50 Hz
Power input ......................................... <1.8 W
Switching capacity (connector L1) .. 1000 W (resistive load)

...............................................................

500 W (inductive load)

   Devices with mainly resistive load are, e.g., light bulbs, heaters, etc. 

 

  Powered devices with inductive load are, e.g., engines, control gears, con-

ventional transformers, energy-saving bulbs, etc.

Mounting position ..............................  Wall mounting (please observe mounting position, 

see section “Installation and connection”)

Protection class ................................. IP55
Switching threshold........................... adjustable, 3 - 1000 lux
Switch-on time ...................................  2, 4, 6 or 8h, selectable (or switching on/off auto-

matically,  depending  on  the  ambient  brightness, 

switching delay 10 s)

Ambient temperature ........................ -20 °C to +50 °C
Dimensions (H x W x D)..................... 105 x 79 x 36 mm
Weight .................................................. approx. 136 g

Summary of Contents for 1362940

Page 1: ...mit Schutzleiter Installationsseitig muss eine allpolige Trennvorrichtung von der Netz spannung vorgesehen werden z B FI Schutzschalter Das Produkt entspricht der IP55 es darf im Außenbereich montiert und betrieben werden Montieren Sie es jedoch niemals an oder in Fahrzeu gen Das Produkt darf niemals in oder unter Wasser betrieben werden da durch wird es zerstört Außerdem besteht Lebensgefahr durc...

Page 2: ...rs kann die aktuelle Helligkeit als Schaltschwelle programmiert werden Halten Sie den Taster zum Speichern der aktuellen Helligkeit länger als 1 Sekunde gedrückt Wenn Sie den Drehregler 7 bewegen so wird die manuelle Schaltschwelle gelöscht und wieder die Einstellung des Drehreglers verwendet Funktionstest Wollen Sie nach der Montage einen Funktionstest durchführen gehen Sie wie folgt vor Drehen S...

Page 3: ...le 6 Rubber seals of the two cable grom mets 7 Control knob for brightness adjust ment 1 2 3 5 7 1 6 4 G Operating instructions Timer with twilight switch Item no 1362940 Intended use The product features a brightness sensor integrated on the front side Thus a con sumer load connected to the product can be switched on or off depending on the ambient brightness The brightness threshold and the turn...

Page 4: ...f the twilight switch the current brightness can be programmed as switching threshold Impress the push button for more than 1 second to save the current brightness If you turn the control knob 7 the manual switching threshold will be dele ted and the setting of the control dial will be applied Function test If you want to perform a function test after installation proceed as follows Move the right...

Page 5: ...ci est relié à la partie inférieure par un cordon en plas tique 1 Trous pour le montage mural 2 Capteur de luminosité 3 Molette de réglage pour le réglage de l heure 4 Touche M pour la mémorisation de la valeur de luminosité actuelle 5 Bornes à vis pour les câbles de rac cordement 6 Joints d étanchéité pour les passages de câble 7 Molette de réglage pour le réglage de la luminosité 1 2 3 5 7 1 6 4...

Page 6: ...on renfoncé M 4 sur le rebord droit de l interrupteur crépusculaire per met de programmer la valeur de luminosité actuelle comme seuil de commutation Maintenez le bouton enfoncé pendant plus de 1 seconde pour mémoriser la valeur de luminosité actuelle Si vous déplacez la molette de réglage 7 le seuil de commutation manuelle sera supprimé et la molette de réglage reprend sa fonction initiale Test d...

Page 7: ... voor opslaan van de actue le helderheid 5 Schroefklemmen voor aansluitkabels 6 Rubberafdichtingen van de twee ka beldoorgangen 7 Draaiknop voor helderheidsinstelling 1 2 3 5 7 1 6 4 O Gebruiksaanwijzing Timer met schemerschakelaar Bestelnr 1362940 Beoogd gebruik Het product beschikt over een aan de voorkant geïntegreerde helderheidssensor Een op het product aangesloten verbruiker kan daardoor afh...

Page 8: ...4 op de rechterrand va de schemer schakelaar kan de actuele helderheid als schakeldrempel worden geprogram meerd Houd de toets voor het opslaan van de actuele helderheid langer dan 1 seconde ingedrukt Als u de draaiknop 7 beweegt wordt de handmatige schakeldrempel ge wist en de instelling van de draaiknop gebruikt Werkingstest Ga als volgt te werk als u na de montage een werkingstest wilt doorvoer...

Reviews: