background image

RVP user's guide

Document part number: H-1000-3322-05-D

RVP user's guide

www.renishaw.com

 

 

Issued 06 2022

1

Summary of Contents for RVP

Page 1: ...RVP user s guide Document part number H 1000 3322 05 D RVP user s guide www renishaw com Issued 06 2022 1...

Page 2: ...shaw plc or its subsidiaries Other brand product or company names are trade marks of their respective owners Third party licences Third party licence information can be found in the following UCCsuite...

Page 3: ...ed with care Changes to Renishaw products Renishaw reserves the right to improve change or modify its hardware or software without incurring any obligations to make changes to Renishaw equipment previ...

Page 4: ...7 EP2035719 EP2140318 EP2167911 EP2431707 EP2564151 EP2764324 EP3004797 EP3052926 EP3289314 EP3322959 EP3542130 JP2016 533484 JP2018 522240 JP2019 536032 JP2021 193400 JP5196356 JP5350216 JP5425476 JP...

Page 5: ...terference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruct...

Page 6: ...ACH regulation Information required by Article 33 1 of Regulation EC No 1907 2006 REACH relating to products containing substances of very high concern SVHCs is available at www renishaw com REACH Chi...

Page 7: ...ING Avoid touching the probe including counter balance arms modules and ACM when attached to the REVO 2 head especially when it is engaged servo LED green and the system is ready for measurement If co...

Page 8: ...y 0 to 80 non condensing Electrical specification The REVO 2 head and probe electronics are powered from the UCC S5 The head motors are powered from the SPA3 The VPCP and VMCP are powered by a separat...

Page 9: ...llation and user s guide SFP2 H 1000 5365 User s guide RVP H 1000 3322 User s guide RFP1 H 1000 5430 Installation guide UCC S5 H 1000 7598 Installation guide SPA3 2 H 1000 5364 Installation user s gui...

Page 10: ...s that are automatically interchangeable with all other probe options available for REVO This flexibility means that the optimum tool can be selected to inspect a wide range of features all on one CMM...

Page 11: ...st between light and dark areas of the image Data points are projected on to the location where the image contrast changes from light to dark A detailed calibration model of the lens system transforms...

Page 12: ...System components overview RVP user s guide www renishaw com Issued 06 2022 12...

Page 13: ...VA90 calibration adaptor shown fitted to VA11 The VA90 calibration adaptor A 5378 0091 does not include the VA11 RVP probe RVP is the probe component of the system that houses the sensor and digital...

Page 14: ...RVP ACM is compatible with VM11 2 attaching magnetically to a kinematic ring on the module VA11 calibration artefact and VA90 calibration adaptor The VA11 is a dedicated calibration artefact used to...

Page 15: ...Dimensional information RVP REVO vision probe Vision modules RVP user s guide www renishaw com Issued 06 2022 15...

Page 16: ...Angle change mirror RVP user s guide www renishaw com Issued 06 2022 16...

Page 17: ...Change ports VA11 calibration artefact RVP user s guide www renishaw com Issued 06 2022 17...

Page 18: ...VA90 calibration adaptor fitted to VA11 NOTE Dimensions in mm in RVP user s guide www renishaw com Issued 06 2022 18...

Page 19: ...3 Hand tighten the fixing screw into the T nut and repeat the process for the next fixing screw 4 Position the VPCP VMCP and tighten both fixing screws using the hexagonal key supplied NOTE The image...

Page 20: ...ets will ensure the pillar is fitted in the correct orientation 6 For use with ACM VA90 can be fitted to the VA11 kinematic mount and the calibration pillar fitted instead to the kinematic mount on th...

Page 21: ...RVP user s guide www renishaw com Issued 06 2022 21...

Page 22: ...d for both front and back lighting applications The image on the left shows a correctly exposed back lit hole The back edge of the hole is sharp and there is good contrast between the material and the...

Page 23: ...on ball seating and permanent magnet is available from your Renishaw supplier part number A 1085 0016 It comprises strips of yellow tack material Use the yellow tack to clean the areas indicated with...

Page 24: ...st be taken to avoid damaging the optical coating or scratching the glass Latex gloves should be worn during the cleaning procedure and no attempt to directly touch the optical windows should be made...

Page 25: ...tand off This is the distance between the end of the vision module and the plane at which a feature will be at the sharpest focal distance to provide optimum image capture RVP user s guide www renisha...

Page 26: ...that will be projected onto the CMOS sensor when the correct stand off distance is used Any feature requiring inspection with RVP must be located within the field of view to allow inspection RVP user...

Page 27: ...ff distance and still be measured with acceptable levels of metrology performance If features are measured outside the recommended depth of field range metrology performance and accuracy will decrease...

Page 28: ...ails please visit our main website at www renishaw com contact Renishaw plc New Mills Wotton under Edge Gloucestershire GL12 8JR United Kingdom T 44 0 1453 524524 F 44 0 1453 524901 www renishaw com c...

Reviews: