Cleaning the RVP system
CAUTION:
Always adhere to the safety instructions given on the general safety recommendations and instructions in this
document. Failure to do so could lead to personal injury.
Following the simple procedures given below will prolong the operational life and maintain the high performance of the system. The user
should determine the frequency of inspection and maintenance actions according to the conditions of use.
Kinematic couplings
The kinematic coupling mechanisms incorporated throughout the system have precision ball seating and permanent magnets. It is
recommended that all these features be cleaned before first use, and thereafter at regular intervals.
A cleaning kit for the precision ball seating and permanent magnet is available from your Renishaw supplier (part number A-1085-0016). It
comprises strips of yellow tack material. Use the yellow tack to clean the areas indicated with arrows numbered [1] on the image below.
With clean hands, tear off a small piece, shape into a small ball and press into / onto each of the features in turn, rotating to a fresh piece of
material as you work around.
CAUTION:
Ensure no yellow tack debris is left on the surface. The yellow tack should not be used for the electrical contacts [2] or
the optical windows [3].
Electrical contacts
The electrical contacts, indicated with arrows numbered [2] in the image below, should be carefully cleaned with an alcohol-based cleaner (e.g.
IPA) and a lint-free bud. The frequency of cleaning depends on the local environmental conditions, but should be at least every five hundred
changes.
RVP user's guide
www.renishaw.com
Issued 06 2022
23
Summary of Contents for RVP
Page 12: ...System components overview RVP user s guide www renishaw com Issued 06 2022 12...
Page 16: ...Angle change mirror RVP user s guide www renishaw com Issued 06 2022 16...
Page 17: ...Change ports VA11 calibration artefact RVP user s guide www renishaw com Issued 06 2022 17...
Page 21: ...RVP user s guide www renishaw com Issued 06 2022 21...