52
Troubleshooting
NOTE:
The MIH contains no user serviceable parts and should be
returned to Renishaw if suspected faulty.
Checks/remidial action:
•
Ensure shank mounting screws are tight and shank is securely
mounted in machine machine quill
•
Inspect autojoint probe connection contacts for damage and
contamination. Clean with a stiff brush if necessary.
•
Ensure probe set-up is locked onto probe head correctly using
the autojoint key.
•
Ensure maximum extension bar of 300 mm (11.81 in) is not
exceeded and extensions longer than 150 mm (5.91 in) are
supported on lock-up.
•
If low battery indicator is shown, replace battery. If not, head may
be faulty (see note above).
•
Ensure battery is present and is inserted correctly (refer to
section 4, ‘Installation’ for correct procedure).
•
Ensure simultaneous operation when appropriate (e.g. to enter
sequence mode, if buttons are not pressed simultaneously,
memory mode is entered).
•
On time-out (no button presses or head movement for a period of
time) the LCD will revert to simple mode if locked, or power down
if unlocked.