Question / Error / Problem
Cause
Troubleshooting / Solution
Can resin be applied to the
model?
For example, for orthodontic
reworking or in order to fabri
-
cate an orthodontic appliance
on the printed model?
•
Yes, this is possible. Ensure that before use, a resin/
resin separator is used. If a separator is not used,
the applied resin bonds with the filament model and
can no longer be lifted after curing.
Can the multi-use filament
be milled? Would it have a
different surface structure
afterwards?
•
As it contains plaster, SIMPLEX multi-use can be
easily worked with rotary instruments and a scalpel.
If the splints are very close to
each other, is working with an
intermediate film permitted?
•
Yes, this is possible.
If an intermediate film is used,
is there a risk that the splints
will not be seated tightly
enough?
•
Observe the manufacturer recommendations of the
splint material / system used.
Worry that in the case of
slender or narrow tooth tips,
the splint will not reach this
point, in other words that it
does not reach low enough.
•
Observe the manufacturer recommendations of the
splint material / system used.
Does the model require insu-
lation before thermoforming
with a film?
•
That depends on what film is used for thermoform
-
ing. Recommendations for model insulation are
provided in the instructions for use of the respective
film. Observe the manufacturer recommendations.
Small holes in the film, heat
-
ing.
•
Possible cause: Small particles of dust were present
on the film that burned during heating. Ensure that
the film is free from dust.