background image

II 

 

 

LIMITED WARRANTY 

   

Renesas warrants its user system interface cables to be manufactured  

  in accordance with published specifications and free from defects in  
  material and/or workmanship. Renesas will repair or replace any  
  user system interface cables determined to be defective in material  
  and/or workmanship. User system interface cables are wearing parts  
  which Renesas will not repair or replace if damaged and/or worn  
  through use. The foregoing shall constitute the sole remedy for any  
  breach of Renesas's warranty. This warranty extends only to you, the  
  original Purchaser. It is not transferable to anyone who subsequently  
  purchases the user system interface cable from you. Renesas is not 
  liable for any claim made by a third party or made by you for a third 
 party. 

DISCLAIMER 

   

RENESAS MAKES NO WARRANTIES, EITHER EXPRESS OR  

  IMPLIED, ORAL OR WRITTEN, EXCEPT AS PROVIDED  
 HEREIN, INCLUDING WITHOUT LIMITATION THEREOF,  
  WARRANTIES AS TO MARKETABILITY, MERCHANTABILITY,  
  FITNESS FOR ANY PARTICULAR PURPOSE OR USE, OR  
  AGAINST INFRINGEMENT OF ANY PATENT. IN NO EVENT  
  SHALL RENESAS BE LIABLE FOR ANY DIRECT, INCIDENTAL  
  OR CONSEQUENTIAL DAMAGES OF ANY NATURE, OR  
  LOSSES OR EXPENSES RESULTING FROM ANY DEFECTIVE  
  USER SYSTEM INTERFACE CABLE, THE USE OF ANY USER  
  SYSTEM INTERFACE CABLE, OR ITS DOCUMENTATION,  
  EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.   
  EXCEPT AS EXPRESSLY STATED OTHERWISE IN THIS  
  WARRANTY, THIS USER SYSTEM INTERFACE CABLE IS SOLD  
  "AS IS ", AND YOU MUST ASSUME ALL RISK FOR THE USE  
  AND RESULTS OBTAINED FROM THE USER SYSTEM  
 INTERFACE CABLE. 

Summary of Contents for H8S/2615 Series

Page 1: ...ook over all the business of both companies Therefore although the old company name remains in this document it is a valid Renesas Electronics document We appreciate your understanding Renesas Electronics website http www renesas com April 1st 2010 Renesas Electronics Corporation Issued by Renesas Electronics Corporation http www renesas com Send any inquiries to http www renesas com inquiry ...

Page 2: ...ct for an application categorized as Specific or for which the product is not intended where you have failed to obtain the prior written consent of Renesas Electronics The quality grade of each Renesas Electronics product is Standard unless otherwise expressly specified in a Renesas Electronics data sheets or data books etc Standard Computers office equipment communications equipment test and meas...

Page 3: ...H8S 2615 Series FP 80Q User System Interface Cable HS2615ECH61H for E6000 Emulator User s Manual User s Manual Rev 2 0 2003 04 ...

Page 4: ......

Page 5: ... system interface cable must only be used for the above purpose Improvement Policy Renesas Technology Corp including its subsidiaries hereafter collectively referred to as Renesas pursues a policy of continuing improvement in design performance functions and safety of the user system interface cable Renesas reserves the right to change wholly or partially the specifications design user s manual an...

Page 6: ...from you Renesas is not liable for any claim made by a third party or made by you for a third party DISCLAIMER RENESAS MAKES NO WARRANTIES EITHER EXPRESS OR IMPLIED ORAL OR WRITTEN EXCEPT AS PROVIDED HEREIN INCLUDING WITHOUT LIMITATION THEREOF WARRANTIES AS TO MARKETABILITY MERCHANTABILITY FITNESS FOR ANY PARTICULAR PURPOSE OR USE OR AGAINST INFRINGEMENT OF ANY PATENT IN NO EVENT SHALL RENESAS BE ...

Page 7: ...rt may be reproduced or duplicated in any form in hard copy or machine readable form by any means available without Renesas s prior written consent Other Important Things to Keep in Mind 1 Circuitry and other examples described herein are meant merely to indicate the characteristics and performance of Renesas s semiconductor products Renesas assumes no responsibility for any intellectual property ...

Page 8: ...llow this symbol to avoid possible injury or death DANGER DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION CAUTION indicates a potentially hazardous situation which if not avoided may result in minor or modera...

Page 9: ... in PERSONAL INJURY The USER PROGRAM will be LOST 1 Do not repair or remodel the emulator product by yourself for electric shock prevention and quality assurance 2 Always switch OFF the E6000 emulator and user system before connecting or disconnecting any CABLES or PARTS 3 Always before connecting any CABLES make sure that pin 1 on both sides are correctly aligned ...

Page 10: ...of bodily injury such as aerospace aeronautics nuclear power combustion control transportation traffic safety equipment or medical equipment for life support 4 Design your application so that the product is used within the ranges guaranteed by Renesas particularly for maximum rating operating supply voltage range heat radiation characteristics installation conditions and other characteristics Rene...

Page 11: ......

Page 12: ...he Renesas s original microcomputer H8S 2615 series The HS2615ECH61H is a user system interface cable that connects an H8S 2615 series E6000 emulator HS2612EPI61H hereinafter referred to as the emulator to the IC socket for a FP 80Q package for the H8S 2615 series MCU on the user system ...

Page 13: ... IC Socket 5 2 2 2 Soldering IC Socket 5 2 2 3 Inserting Cable Head 6 2 2 4 Fastening Cable Head 6 2 2 5 Fastening Cable Body 8 2 3 Recommended Dimensions for User System Mount Pad 9 2 4 Dimensions for User System Interface Cable Head 10 2 5 Resulting Dimensions after Connecting User System Interface Cable 11 Section 3 Installing the MCU to the User System 12 Section 4 Verifying Operation 14 Secti...

Page 14: ...n the user system Figure 1 shows the configuration of the HS2615ECH61H user system interface cable for the FP 80Q package User system IC socket Cable head Screws M2 x 12 mm with flat washers for fastening cable head Screws M2 x 8 mm with flat washers Socket cover To emulator station Cable body Figure 1 HS2615ECH61H User System Interface Cable ...

Page 15: ...ntity Remarks 1 Cable body 1 Flat cable 2 Cable head 1 3 IC socket 1 For the FP 80Q package 4 Socket cover 1 For installing an FP 80Q packaged MCU 5 Screws M2 x 12 mm 4 For fastening cable head with four flat washers 6 Screws M2 x 8 mm 4 For installing an FP 80Q packaged MCU with four flat washers 7 Documentation 1 User s manual for HS2615ECH61H this manual ...

Page 16: ... make sure that pin 1 on both sides are correctly aligned 2 The user system interface cable dedicated to the emulator must be used To connect the cable body to the emulator station follow the instructions below 1 Make sure the user system and emulator station are turned off CAUTION When connecting or removing the user system interface cable apply force only in the direction suitable for connection...

Page 17: ...4 Emulator station E 6 0 0 0 Cable body connector User system interface cable Figure 2 Connecting User System Interface Cable to Emulator Station ...

Page 18: ...result in PERSONAL INJURY The USER PROGRAM will be LOST To connect the cable head to the user system follow the instructions below 2 2 1 Installing IC Socket After checking the location of pin 1 on the IC socket apply epoxy resin adhesive to the bottom of the IC socket for an FP 80Q package and fasten it to the user system before soldering 2 2 2 Soldering IC Socket After fastening solder the IC so...

Page 19: ...crewdriver whose head matches the screw head 2 The tightening torque must be 0 0785 N m or less If the applied torque cannot be accurately measured stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening If a screw is tightened too much the screw head may break or an IC socket contact error may be caused by a crack in the IC so...

Page 20: ...ernating between screws on opposing corners Take special care such as manually securing the IC socket soldered area to prevent the soldered IC socket from being damaged by overtightening the screws or twisting the components Pin 1 Cable head IC socket IC149 080 017 B5 manufactured by YAMAICHI ELECTRONICS Co Ltd Screws M2 x 12 mm with flat washers User system Figure 3 Connecting User System Interfa...

Page 21: ...8 2 2 5 Fastening Cable Body Connect the cable body to the cable head Cable body Cable head Remove jig Push the remove jig User system Removing Figure 4 Fastening Cable Body ...

Page 22: ...th an IC socket for an FP 80Q package IC149 080 017 B5 manufactured by YAMAICHI ELECTRONICS Co Ltd Note that the dimensions in figure 5 are somewhat different from those of the actual chip s mount pad Unit mm 0 35 0 65 x 19 12 35 0 1 0 1 0 05 0 65 0 05 0 65 x 19 12 35 0 1 14 70 max 20 50 min 0 65 0 05 Figure 5 Recommended Dimensions for Mount Pad ...

Page 23: ...User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6 Unit mm Tolerance 0 5 mm 63 5 63 5 17 0 14 46 29 5 29 5 Figure 6 Dimensions for User System Interface Cable Head ...

Page 24: ... after connecting the user system interface cable head to the user system are shown in figure 7 9 4 21 5 Cable head User system Unit mm Tolerance 0 5 mm IC socket IC149 080 017 B5 manufactured by YAMAICHI ELECTRONICS Co Ltd Figure 7 Resulting Dimensions after Connecting User System Interface Cable ...

Page 25: ...ew head may break or an IC socket contact error may be caused by a crack in the IC socket solder 4 If the MCU does not operate correctly cracks might have occurred in the solder Check conduction with a tester and re solder the IC socket if necessary Check the location of pin 1 before inserting the MCU into the IC socket on the user system as shown in figure 8 After inserting the MCU fasten the soc...

Page 26: ...13 MCU Pin 1 IC socket IC149 080 017 B5 manufactured by YAMAICHI ELECTRONICS Co Ltd User system Screws M2 x 8 mm with flat washers Socket cover Figure 8 Installing MCU to User System ...

Page 27: ...s refer to the H8S Series E6000 Emulator Supplementary Information HS2628EPI61HE To use the emulator internal clock Select the clock in the emulator station as the system clock φ by using the CLOCK command emulator command To use the external clock on the user system Select external clock Target or Target 2 with the CLOCK command emulator command Supply the external clock from the user system to t...

Page 28: ...l objects on the user system interface cable 5 While the emulator station is connected to the user system with the user system interface cable force must not be applied to the cable head Place the emulator station user system interface cable and user system as shown in the example in figure 10 User system Cable Emulator station Place components so that the cable body and cable head are parallel to...

Reviews: