2.4 Grid codes

16.3KG

16.3KG

16.3KG

18.3KG

18.3KG

18.3KG

21.6KG

98.1%

97.5%

99.9%

97.8%

97.2%

99.9%

Integrated

Integrated

Integrated

Integrated

Integrated

Integrated

Integrated

Integrated

Integrated (Type III)

Integrated (Type III)

                                                 395 x 330 x 185mm                      455x390x160mm                              455x390x190mm                                               

LCD

RS485 (Standard), Wifi or GPRS

-25 

 ~ 60 

0-100%

≤ 4000m

< 0.2W

Transformerless

Natural Convection

IP65

< 30dB

5 / 7 / 10 years

C10/11, PEA, MEA, G98, G99, EN50549,CEI 0-21, CEI 0-16, IEC61727, IEC62116, 

IEC60068, IEC61683

IEC 62109-1, IEC 62109-2

EN 61000-3-2, EN 61000-3-3, EN 61000-3-11, EN 61000-3-12, EN 61000-6-2,

EN 61000-6-3, IEC 61000-4-16, IEC 61000-4-18, 4-29

Protection

DC Insulation Monitoring

Input Reverse Polarity Protection

Anti-island Protection

Residual Current Monitoring

Over-heat Protection

AC Overcurrent Protection

AC Short-circuit Protection

AC Overvoltage Protection

DC Surge Protection

AC Surge Protection

General Data

Size(Width*Height*Depth)

Weight

User Interface

Communication

Ambient Temperature Range

Relative Humidity

Operating Altitude

Standby Self Consumption

Topology

Cooling

Protection Grades

Noise

Warranty

Certifications & Standards

Grid Regulation

Safety Regulation

EMC

98.1%

97.5%

99.9%

Belgium power Grid.

UK power Grid.

China power Grid, meet Grid standards “CN-NBT”.

France power Grid, meet Grid standards “VDE 0126”.

Poland power Grid.

Germany power Grid, meet Grid standards “BDEW-MV”.

Germany power Grid, meet Grid standards “VDE 0126”.

Italy power Grid, meet Grid standards “CEI 0-16”.

UK power Grid.

Greece Island power Grid.

Czech Republic power Grid, meet Grid standards “EN50438Y2007-CZ”.

India power Grid.

Korea power Grid.

Sweden power Grid.

China power Grid, Grid voltage range

160-290V

Grid frequency range

47-53HZ.

China power Grid, meet standards“CQC ”.

India power Grid, meet Grid standards “IEC61727”.

Brazil power Grid , meet Grid standards “NBT 16150”.

Sri Lanka power Grid, meet Grid standards “IEC61727”.

Mexico power Grid, meet Grid standards “IEC61727 60HZ”.

New Zealand power Grid, meet Grid standards “NZ4777”.

Philippines power Grid, meet Grid standards “IEC61727 60HZ spec”.

Sri Lanka power Grid, Grid voltage range

160-290V, Grid frequency range

47-53HZ.

Thailand power Grid.

Thailand power Grid, Grid voltage range

160-290V, Grid frequency range

47-53HZ.

Vietnam power Grid.

Vietnam power Grid, Grid voltage range

160-290V, Grid frequency range

47-53HZ.

Thailand power Grid.

Thailand power Grid, Grid voltage range

160-290V, Grid frequency range

47-53HZ.

Tunisia power Grid.

Tunisia power Grid, Grid voltage range

160-290V, Grid frequency range

47-53HZ.

C10/11

G59

China

VDE0126-FR

EN50549-PL

BDEW-DE

VDE0126-DE

CEI0-16

G83

Greece Island

EN50549-CZ

IEC61727

Korea

EN50549-SW

China-W

China-H

IEC61727-IN

Brazil

IEC61727-SL

Mexico

NZ4777

Philippines

IEC61727-SL-W

PEA

PEA-W

IEC61627-VN

IEC61627-VN-W

MEA

MEA-W

Tunisia

Tunisia-W

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

Description

National/Regional Grid Code

No.

Summary of Contents for R3 Micro Series

Page 1: ...R3 4K DT R3 5K DT R3 6K DT R3 8K DT R3 10K DT R3 12K DT R3 15K DT UserManual Series R3 Note...

Page 2: ...ackageinformation 8 3 2Installationenvironment 8 3 3Installationposition 9 3 4Mountingprocedure 10 3 5Electricalconnection 11 3 6StartingtheInverter 15 4 UserInterface 15 4 1Ledandkey 15 4 2LCDdisplay...

Page 3: ...red that the open circuit voltage of the PV string never exceeds the maximum permissible input voltage of 1000V DC The PV string open circuit voltage during parallel string operation is 950V Higher vo...

Page 4: ...mainly on internal and ambient temperatures The limitation is calculated continuously and always allows the maximum possible amount of energy to be produced Please use the tool supplied by Renac Power...

Page 5: ...id meet Grid standards BDEW MV Germany power Grid meet Grid standards VDE 0126 Italy power Grid meet Grid standards CEI 0 16 UK power Grid Greece Island power Grid Czech Republic power Grid meet Grid...

Page 6: ...ed person There are 2 PV connectors for R3 4 5 6 8 10 12K DT and 3 PV connectors for R3 15K DT There are 2 PV connectors for R3 4 5 6 8 10 12K DT and 3 PV connectors for R3 15K DT Quality Certificate...

Page 7: ...s section of ac cables Description A B C D No Figure 3 5 Strip off N L1 L2 L3 cables 2 Strip off PE cable as gure 3 6 1 Add breaker or fuse to AC side the speci cation should be more than 1 25 times o...

Page 8: ...the terminal accord ing to the wire sequence L1 L2 L3 N PE so that the insulating terminal is ush with the surface of the terminal and the crimping screw torque is 2 0 0 1N m 6 Insert the main part of...

Page 9: ...cable connected to the two string correctly and it s polarity 3 The unused terminals are covered Starting the inverter Close the DC and AC circuit breaker If the solar panels provide enough energy the...

Page 10: ...t 1 2 3 4 Press pushbutton less than 1 sec several times until you reach the Setting menu Press pushbutton long in order to enter the setting menu Press pushbutton less than 1 sec several times until...

Page 11: ...nverter is 60 months from the date of installation and no more than 66 months 5 5 years from the date of shipment from factory Please report defective device with a brief error description and SN code...

Page 12: ...o factory or and repaired products are sent from factory to user 5 2 Service after warranty expiration 1 2 3 4 Possible actions Isolation Fault Isolation Fault 2 LCD display Clearable Fault Fault 1 Ch...

Page 13: ...AC P OW E R T E C H N O L O GY C O LT D Add Block 6 No 2 West Jinzhi Road Suzhou National Hi Tech District Suzhou China Tel 86 0512 66677278 info renacpower com www renacpower com SMARTENERGYFORBETTE...

Reviews: