eng
Rapid charger
Input 100 – 240 V~; 50 – 60 Hz; 70 W
Output 21.6 V–
---
protective insulated, radio interference suppressed
Rapid charger
Input 100 – 240 V~; 50 – 60 Hz; 90 W
Output 21.6 V–
---
protective insulated, radio interference suppressed
Rapid charger
Input 100 – 240 V~; 50 – 60 Hz; 290 W
Output 21.6 V–
---
protective insulated, radio interference suppressed
Type of protection
REMS Lumen 5000 / 7000 /10000
IP65
REMS Lumen 2800 22 V
IP20
Light fl ux brightness stage
REMS Lumen 5000
5,000 lm
REMS Lumen 7000
7,000 lm
REMS Lumen 10000
(brightness stage 1/2)
5,000/10,000 lm
REMS Lumen 2800 22 V
(brightness stage 1/2/3)
1,100 / 2,000 / 2,800 lm
Light duration, REMS Lumen 2800 22 V
Operating hours h
Designation
Stage 1
Stage 2
Stage 3
(1,100 lm)
(2,000 lm)
(2,800 lm)
Li-Ion 21.6 V, 1.5 Ah battery
3.3 1.4 1.0
Li-Ion 21.6 V, 2.5 Ah battery
5.4 2.4 1.6
Li-Ion 21.6 V, 5.0 Ah battery
10.9 4.8 3.2
Li-Ion 21.6 V, 9.0 Ah battery
19.6 8.6 5.7
1.6. Weights
REMS Lumen 5000
1.8 kg (4.0 lb)
REMS Lumen 7000
2.2 kg (4.9 lb)
REMS Lumen 10000
3.0 kg (6.6 lb)
REMS Lumen 2800 22 V without battery
1.7 kg (3.7 lb)
Li-Ion 21.6 V, 1.5 Ah battery
0.4 kg (0.9 lb)
Li-Ion 21.6 V, 2.5 Ah battery
0.4 kg (0.9 lb)
Li-Ion 21.6 V, 5.0 Ah battery
0.8 kg (1.8 lb)
Li-Ion 21.6 V, 9.0 Ah battery
1.1 kg (2.4 lb)
REMS telescopic stand 3B
2.0 kg (4.4 lb)
2. Preparations for Use
2.1. Electrical connection
WARNING
WARNING
Note the mains voltage!
Before connecting the LED fl ood lamp, the rapid charger or the power supply, check
whether the voltage given on the rating plate corresponds to the mains voltage. Only connect power tools of
protection class I to a socket/extension lead with a functioning protective contact. On building sites, in a wet
environment, indoors and outdoors or under similar installation conditions, only operate the electrical device
on the mains with a fault current protection switch (FI switch) which interrupts the power supply as soon as the
leakage current to earth exceeds 30 mA for 200 ms.
Rechargeable batteries
Total discharging by undervoltage
The Li-Ion batteries may not drop below a minimum voltage because otherwise the battery could be damaged
by “total discharge”, see graduated charging state display. The cells of the REMS Li-Ion battery are delivered
pre-charged to approx. 40 %. Therefore the Li-Ion batteries must be charged before use and recharged
18
Summary of Contents for Lumen 10000
Page 2: ...Fig 1 Fig 2 8 7 6 4 5 8 9 11 6 3 3...
Page 3: ...Fig 3 7 9 3 12 11 10 1 2 8...
Page 4: ...Fig 4 8 13 14 8 14...
Page 172: ...rus 1 4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 b c 2 a b c d e f 3 a 172...
Page 173: ...rus b c d e f g h 4 a b c d e f g h 5 a b 173...
Page 174: ...rus c d e f 130 C g 6 a b I 174...
Page 175: ...rus 1 I II SCPST 1 0 m EAC 175...
Page 182: ...ell 1 4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 a b c 2 a b c d e f 3 a b 182...
Page 183: ...ell c d e f g h 4 a b c d e f g h 5 a b c d e 183...
Page 200: ...bul 1 4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 a 2 a 3 200...
Page 201: ...bul 4 a 5 201...
Page 202: ...bul 130 C 6 I 202...
Page 236: ...236...
Page 237: ...237...
Page 238: ...238...