28
Listening Mode
There are multiple usages by entering this mode:
•
Version command class: To get application software version, the
Z-Wave protocol version and the supported Z-Wave command
version of this controller.
•
Manufacturer command class: To get the manufacture ID, product
type ID and the product ID of this controller.
•
Scene configuration command class: Home gateway can bundle a
scene ID to a group ID using this command.
•
Association command class: To create and maintain associations
in this remote.
Step
Setup Key
LED Indication Status
1
Press & hold
for 3 seconds
•
“
OK
"
LED on
2
Place the two controller
close to each other
3
Type
“
8364
"
on the
setup number keypad
•
“
OK
"
LED flashes
once for each number
input
•
“
OK
"
LED keeps
blinking after entering
the 4-digit
4
Listening mode will
automatically exit after 1
minute of inactivity
•
“
OK
"
LED flashes
once then turns off when
exiting listening mode
•
Replication completed
Note1: The mode must not be exited during communication process
with another controller. Please wait for entire communication process
to be completed.
Note2: It is not allowed to enter any user input from the remote's hard
key after entry this Mode.